Reference levels at European level for cardiac interventional procedures.

نویسندگان

  • R Padovani
  • E Vano
  • A Trianni
  • C Bokou
  • H Bosmans
  • D Bor
  • J Jankowski
  • P Torbica
  • K Kepler
  • A Dowling
  • C Milu
  • V Tsapaki
  • D Salat
  • J Vassileva
  • K Faulkner
چکیده

In interventional cardiology, a wide variation in patient dose for the same type of procedure has been recognised by different studies. Variation is almost due to procedure complexity, equipment performance, procedure protocol and operator skill. The SENTINEL consortium has performed a survey in nine european centres collecting information on near 2000 procedures, and a new set of reference levels (RLs) for coronary angiography and angioplasty and diagnostic electrophysiology has been assessed for air kerma-area product: 45, 85 and 35 Gy cm2, effective dose: 8, 15 and 6 mSv, cumulative dose at interventional reference point: 650 and 1500 mGy, fluoroscopy time: 6.5, 15.5 and 21 min and cine frames: 700 and 1000 images, respectively. Because equipment performance and set-up are the factors contributing to patient dose variability, entrance surface air kerma for fluoroscopy, 13 mGy min(-1), and image acquisition, 0.10 mGy per frame, have also been proposed in the set of RLs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proposal of reference levels for cardiac interventional procedures. An European Coordination Action

Interventional cardiology is a medical specialty widely known to deliver high radiation dose to patients, who may receive, in some complex cases, skin doses over the threshold for deterministic effects. Because several studies have demonstrated large variability in delivered doses, European SENTINEL consortium has carried out a patient dose survey to propose regional Reference Levels (RL) as a ...

متن کامل

Evaluation of Patients’ effective dose in nuclear medicine department of Isfahan in order to define a local reference level

Introduction: Nowadays, nuclear medicine (NM) imaging indications in medical practice is raising. A practical step to get closer to the optimization rule is collecting data about patients’ exposure and definition of guidance levels. The aim of this study was definition of local reference level in Isfahan city. Materials and Methods: Questionnaires were given...

متن کامل

Assessment of Patient Radiation Dose in Interventional Procedures at Shahid Madani Heart Center in Khorramabad, Iran

Introduction: Coronary angiography is the most common angiographic procedure for diagnosis and treatment of the heart diseases. Herein, we aimed to evaluate the entrance surface dose (ESD), dose area product (DAP), as well as cancer risk in interventional cardiology procedures. Materials and Methods: This study was conducted during July-December 2015 at Shahid Madani Heart Center in Khorramabad...

متن کامل

Examining the difficulty pathways of can-do statements from a localized version of the CEFR

The Japanese adaptation of the Common European Framework of Reference (CEFR-J) is a tailored version of the Common European Framework of Reference (CEFR), designed to better meet the needs of Japanese learners of English. The CEFR-J, like the CEFR, uses illustrative  descriptors  known  as  can-do  statements,  that  describe  achievement  goals  for five  skills  (listening,  reading,  spoken ...

متن کامل

Are Radiation Exposure Levels Used in Cardiology Dangerous?

Background: The number of interventional cardiology procedures performed has increased rapidly over the past years. While these procedures help physicians avoid using highly complicated invasive methods, it usually leads to high levels of exposure to ionizing radiation of both patients and cardiologist. The dose received by the cardiologist during interventional cardiology procedures is determi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 129 1-3  شماره 

صفحات  -

تاریخ انتشار 2008