Wavefront Distortion Measurement of a Sr Extraction Mirror for the Beam Profile Monitor Using Shack- Hartmann Method

نویسندگان

  • N. Takeuchi
  • T. Mitsuhashi
  • M. Itoh
  • T. Yatagai
چکیده

The wavefront measurement technique using the Shack Hartmann wavefront sensor has been developed for measurement of wavefront distortion of a SR extraction mirror for the beam profile monitor at Photon Factory. The instrument consists of a multi-lens array ( 8x8 array, 250 mm pitch and focal length of 4.5 mm), a beam expander (20:1), an image relay lens system (1:1), a HeNe laser (633 nm) and a digital CCD camera. To analyze positions of focal spot on the CCD in 1/10 of the pixel size, the wave front sensor can measured to be l/30. A dynamic range of the wavefront sensor was designed 12.6 mm max. Performance of the wavefront sensor was tested with an optical flat. With this wavefront sensor, a wavefront error caused by surface deformation of the SR extraction mirror was measured at Beamline 27 of Photon Factory. The correction of the measured wavefront distortion is also described.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of a MEMS-based Shack-Hartmann wavefront sensor with adjustable pupil sampling for astronomical adaptive optics.

We introduce a Shack-Hartmann wavefront sensor for adaptive optics that enables dynamic control of the spatial sampling of an incoming wavefront using a segmented mirror microelectrical mechanical systems (MEMS) device. Unlike a conventional lenslet array, subapertures are defined by either segments or groups of segments of a mirror array, with the ability to change spatial pupil sampling arbit...

متن کامل

Shack-Hartmann wavefront-sensor-based adaptive optics system for multiphoton microscopy.

The imaging depth of two-photon excitation fluorescence microscopy is partly limited by the inhomogeneity of the refractive index in biological specimens. This inhomogeneity results in a distortion of the wavefront of the excitation light. This wavefront distortion results in image resolution degradation and lower signal level. Using an adaptive optics system consisting of a Shack-Hartmann wave...

متن کامل

hack-Hartmann wavefront-sensor-based adaptive optics ystem for multiphoton microscopy

Hartmann wavefront-sensor-based adaptive optics system for multiphoton microscopy. Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use. The MIT Faculty has made this article openly available. Please share how this access benefits you. Your story matters. Abstract. The imaging depth of t...

متن کامل

Determination of wavefront structure for a Hartmann wavefront sensor using a phase-retrieval method.

We apply a phase retrieval algorithm to the intensity pattern of a Hartmann wavefront sensor to measure with enhanced accuracy the phase structure of a Hartmann hole array. It is shown that the rms wavefront error achieved by phase reconstruction is one order of magnitude smaller than the one obtained from a typical centroid algorithm. Experimental results are consistent with a phase measuremen...

متن کامل

Photothermal measurement of absorption and wavefront deformations in UV optics

A measurement system for quantitative registration of transient and irreversible lens effects in DUV optics induced by absorbed UV laser radiation was developed. It is based on a strongly improved Hartmann-Shack wavefront sensor with an extreme sensitivity of ~λ/10,000 rms @ 193nm, accomplishing precise on-line monitoring of wavefront deformations of a collimated test laser beam transmitted thr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998