OBJECTIVE The occlusal patterns are key requirements for the clinical success of oral rehabilitation supported by implants. This study compared the stresses generated by the disocclusion in the canine guide occlusion (CGO) and bilateral balanced occlusion (BBO) on the implants and metallic infrastructure of a complete Brånemark protocol-type denture modified with the inclusion of one posterior short implant on each side. MATERIAL AND METHODS A three-dimensional model simulated a mandible with seven titanium implants as pillars, five of them installed between the mental foramen and the two posterior implants, located at the midpoint of the occlusal surface of the first molar. A load of 15 N with an angle of 45° was applied to a tooth or distributed across three teeth to simulate the CGO or BBO, respectively. The commercial program ABAQUS® was used for the model development, before and after the processing of the data. The results were based on a linear static analysis and were used to compare the magnitude of the equivalent stress for each of the simulations. RESULTS The results showed that the disocclusion in CGO generated higher stresses concentrated on the working side in the region of the short implant. In BBO, the stresses were less intense and more evenly distributed on the prosthesis. The maximum stress found in the simulation of the disocclusion in CGO was two times higher than that found in the simulation of the BBO. The point of maximum stress was located in the neck of the short implant on the working side. CONCLUSIONS Under the conditions of this study, it was concluded that the BBO pattern was more suitable than CGO for the lower complete denture supported by implants without free distal ends.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Number of Implants and Cantilever Design on Stress Distribution in Three-unit Fixed Partial Dentures: a Three-dimensional Finite Element Analysis

Although dental implants have been successfully used for the rehabilitation of fully edentulous and partially edentulous patients, patient’s various conditions constrict the application of implant, or make dental treatment using dental implants very complex and difficult. Implantsupported cantilever prostheses represent that conditions. Becker and Kaiser insisted that alignment problems, extens...

متن کامل

Biomechanical Analysis of the Stresses Generated by Different Disocclusion Patterns in an Implant-supported Mandibular Complete Denture

OBJECTIVES This study evaluated by three-dimensional finite element analysis the tensions generated by different disocclusion patterns (canine guide and bilateral balanced occlusion) in an implant-supported mandibular complete denture. MATERIAL AND METHODS A three-dimensional model of implant-supported mandibular complete denture was fabricated according to the Brånemark protocol. A 5-element...

متن کامل

What occlusion and Disocclusion Standard We Should Use in Complete Dentures Supported by Implants? Literature Review

*Corresponding author: Gustavo Diniz Greco, Doctor of Clinical Dentistry, Universidade Federal de Minas Gerais, Master and Specialist in Prosthodontics, Dentist CRO-MG 30278, Professor of Prosthodontics and Implant Dentistry, FEAD-Minas, Coordinator of the Specialization Program in Prosthodontics, ABO-Seven ponds, DENTAL CENTER W, W FILE Digital Dental Radiology, Brazil, Tel: 3334-3673/3334-333...

متن کامل

Stress Distribution in Natural Tooth and Implant Supported Removable Partial Denture with Different Attachment Types: A Photoelastic Analysis

Background and Aim: Different attachment designs have been developed to connect implant to natural teeth in partial dentures; however, adequate studies have not been performed to determine stress distribution patterns in these designs. The present study aimed to assess stress distribution patterns in natural tooth and implant supported removable partial denture with different attachment designs...

متن کامل

Photoelastic analysis of all-on-four concept using different implants angulations for maxilla.

Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two different angulations and length of the cantilever in fixed implant-supported maxillary complete d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2012