Dynamic Action Potential Restitution Contributes to Mechanical Restitution in Right Ventricular Myocytes From Pulmonary Hypertensive Rats

نویسندگان

  • Matthew E. L. Hardy
  • Eleftheria Pervolaraki
  • Olivier Bernus
  • Ed White
چکیده

We investigated the steepened dynamic action potential duration (APD) restitution of rats with pulmonary artery hypertension (PAH) and right ventricular (RV) failure and tested whether the observed APD restitution properties were responsible for negative mechanical restitution in these myocytes. PAH and RV failure were provoked in male Wistar rats by a single injection of monocrotaline (MCT) and compared with saline-injected animals (CON). Action potentials were recorded from isolated RV myocytes at stimulation frequencies between 1 and 9 Hz. Action potential waveforms recorded at 1 Hz were used as voltage clamp profiles (action potential clamp) at stimulation frequencies between 1 and 7 Hz to evoke rate-dependent currents. Voltage clamp profiles mimicking typical CON and MCT APD restitution were applied and cell shortening simultaneously monitored. Compared with CON myocytes, MCT myocytes were hypertrophied; had less polarized diastolic membrane potentials; had action potentials that were triggered by decreased positive current density and shortened by decreased negative current density; APD was longer and APD restitution steeper. APD90 restitution was unchanged by exposure to the late Na+-channel blocker (5 μM) ranolazine or the intracellular Ca2+ buffer BAPTA. Under AP clamp, stimulation frequency-dependent inward currents were smaller in MCT myocytes and were abolished by BAPTA. In MCT myocytes, increasing stimulation frequency decreased contraction amplitude when depolarization duration was shortened, to mimic APD restitution, but not when depolarization duration was maintained. We present new evidence that the membrane potential of PAH myocytes is less stable than normal myocytes, being more easily perturbed by external currents. These observations can explain increased susceptibility to arrhythmias. We also present novel evidence that negative APD restitution is at least in part responsible for the negative mechanical restitution in PAH myocytes. Thus, our study links electrical restitution remodeling to a defining mechanical characteristic of heart failure, the reduced ability to respond to an increase in demand.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arrhythmogenic substrate in hearts of rats with monocrotaline-induced pulmonary hypertension and right ventricular hypertrophy.

Mechanisms associated with right ventricular (RV) hypertension and arrhythmias are less understood than those in the left ventricle (LV). The aim of our study was to investigate whether and by what mechanisms a proarrhythmic substrate exists in a rat model of RV hypertension and hypertrophy. Rats were injected with monocrotaline (MCT; 60 mg/kg) to induce pulmonary artery hypertension or with sa...

متن کامل

Action potential duration restitution and alternans in rabbit ventricular myocytes: the key role of intracellular calcium cycling.

Action potential duration (APD) restitution properties and repolarization alternans are thought to be important arrhythmogenic factors. We investigated the role of intracellular calcium (Ca2+i) cycling in regulating APD restitution slope and repolarization (APD) alternans in patch-clamped rabbit ventricular myocytes at 34 to 36 degrees C, using the perforated or ruptured patch clamp techniques ...

متن کامل

Effect of -adrenergic blockade on dynamic electrical restitution in vivo

Hao, Steven C., David J. Christini, Kenneth M. Stein, Peter N. Jordan, Sei Iwai, Orville Bramwell, Steven M. Markowitz, Suneet Mittal, and Bruce B. Lerman. Effect of -adrenergic blockade on dynamic electrical restitution in vivo. Am J Physiol Heart Circ Physiol 287: H390–H394, 2004. First published March 4, 2004; 10.1152/ajpheart.00749.2003.—The slope of the action potential duration (APD) rest...

متن کامل

Altered dynamics of action potential restitution and alternans in humans with structural heart disease.

BACKGROUND Restitution kinetics and alternans of ventricular action potential duration (APD) have been shown to be important determinants of cardiac electrical stability. In this study, we tested the hypothesis that APD restitution and alternans properties differ between normal and diseased human ventricular myocardium. METHODS AND RESULTS Monophasic action potentials were recorded from the r...

متن کامل

Restitution slope is principally determined by steady-state action potential duration

Aims The steepness of the action potential duration (APD) restitution curve and local tissue refractoriness are both thought to play important roles in arrhythmogenesis. Despite this, there has been little recognition of the apparent association between steady-state APD and the slope of the restitution curve. The objective of this study was to test the hypothesis that restitution slope is deter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2018