Inductively coupled stent antennas in MRI.

نویسندگان

  • Harald H Quick
  • Hilmar Kuehl
  • Gernot Kaiser
  • Silke Bosk
  • Jörg F Debatin
  • Mark E Ladd
چکیده

The development of intimal hyperplasia following stent deployment can lead to narrowing or even occlusion of the stent lumen. The underlying mechanisms leading to neointimal proliferation within stents remain largely unknown. Long-term evaluation of stent patency requires a noninvasive means for assessing the stent lumen. MR angiography (MRA) has shown potential to provide noninvasive assessment of the vascular system. However, a detailed assessment of the stent lumen with MRI is often hampered by material-dependent susceptibility artifacts, as well as by radiofrequency (RF) eddy currents generated inside the electrically conducting stent mesh. In this study, stent prototypes were designed to act as active resonant structures at the Larmor frequency of the MR system. Employing the principle of inductive coupling, the B(1) fields of the stents were coupled to that of an outside surface coil. The stents thus acted as local RF signal amplifiers. Various stent designs were investigated regarding their coupling to an external coil, signal homogeneity, and suitability for mechanical expansion for implantation purposes. The dependency of flip angle amplification on the quality factor Q of the stents was systematically investigated. Phantom experiments revealed signal amplification in all stent prototypes. Signal enhancement inside and close to the surface of the stents enabled their localization with high contrast in MR images. In vivo imaging experiments in the iliac, renal, and splenic arteries of two pigs confirmed the in vitro findings. Wireless active visualization of stents allows for detailed analysis of the stent lumen with high contrast and spatial resolution. The proposed method could thus provide a powerful diagnostic means for the noninvasive long-term follow-up of stent patency, thereby enhancing our understanding of the mechanisms of restenosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hydrothermal Synthesis of an Ethiodol Based Ferrofluid as a Potential MRI Contrast Agent

In the present work, stable ferrofluids containing oleic acid capped magnetite nanoparticles were synthesized via low temperature hydrothermal method. The physical and chemical properties of the synthesized particles were studied using TEM, XRD, AFM, VSM and PCS techniques. Mean particles size of the samples was between 4.5 and 10 nanometers, depending on experimental conditions. Effect ...

متن کامل

Fabrication of an Inductively Coupled Plasma Antenna in Low Temperature Co-Fired Ceramic

A miniature electrostatic thruster is being developed in Low Temperature Co-fired Ceramic (LTCC) at Boise State University. The thruster is composed of an antenna to create the plasma, a cylinder to contain the plasma, and grids to extract the plasma beam at high velocity. In this work, the development of the inductively coupled plasma (ICP) antenna in LTCC will be presented. This antenna is fa...

متن کامل

Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression

A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...

متن کامل

Biodistribution and pharmacokinetic studies of SPION using particle electron paramagnetic resonance, MRI and ICP-MS.

AIM Superparamagnetic iron oxide nanoparticles (SPIONs) may play an important role in nanomedicine by serving as drug carriers and imaging agents. In this study, we present the biodistribution and pharmacokinetic properties of SPIONs using a new detection method, particle electron paramagnetic resonance (pEPR). MATERIALS & METHODS The pEPR technique is based on a low-field and low-frequency e...

متن کامل

Analysis of Aperture Coupled Microstrip Patch Antennas with a Superstrate Using the Space Domain Closed-Form Green`s Functions

Analysis of aperture-coupled microstrip antennas with a superstrate using space domain closed form Green's functions is presented. Integral equations are derived from applying the boundary conditions on the radiating patch, across the aperture, and on the microstrip feedline. The computation of space domain green's functions is performed using the closed-form. The solution of the integral equat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 48 5  شماره 

صفحات  -

تاریخ انتشار 2002