Monopolar electrocautery versus ultrasonic dissection of the gallbladder from the gallbladder bed in laparoscopic cholecystectomy.
نویسندگان
چکیده
BACKGROUND Gold standard treatment for symptomatic gall stones is laparoscopic cholecystectomy (LC). Ultrasonically activated devices have been used for gall bladder dissection in LC. Harmonic scalpel (HS) is the leading ultrasonically cutting coagulation device offering surgeons important benefits. The main aim of our study was to compare the surgical outcomes of LC performed by HS to that performed by conventional mono-polar diathermy (electro-cautery). METHODS This prospective randomized study was conducted in surgical department of Jinnah Postgraduate Medical Centre, Karachi, during May-October 2013. During this period we selected 92 patients with symptomatic gallstones who underwent LC; these patients were randomly recruited into two groups using sealed opaque envelopes. Group A underwent gallbladder dissection from its bed using mono-polar diathermy, while on the other hand in Group B the dissection was carried out using harmonic scalpel. The outcomes like gallbladder perforation with bile spillage, intra-operative bleeding and operative time were assessed. RESULTS The harmonic scalpel (HS) usage in surgery results in shorter operative time, it also leads to less gallbladder injury, bile leakage and stone spillage (due to minimal lateralization of heat energy) not only this it also leads to less intra-operative blood loss. CONCLUSION Harmonic scalpel is a new innovation in gallbladder surgery it has multiple functions like cutting, coagulation, coaptaion and cavitation which have made it safe, handy, effective and reliable instrument.
منابع مشابه
مقایسه آسیب بافتی حین و پس از جراحی کولهسیستکتومی لاپاراسکوپی با استفاده از انرژی الکتریکی مونوپلار و اولتراسوند
Background: Laparoscopic cholecystectomy is a minimally invasive procedure whereby the gallbladder is removed using laparoscopic techniques. Monopolar electerosurgical energy is the method of dissection of gallbladder from liver bed. Ultrasonic energy causes less thermal damage and suggests an alternative to monopolar elevterocautery. Leptin is a tissue factor and C-reactive protein (CRP) is an...
متن کاملLaparoscopic “Dome-Down” Cholecystectomy With the LCS-5 Harmonic Scalpel
OBJECTIVE Misidentification of ductal anatomy and electrocautery injuries are complications associated with laparoscopic cholecystectomy (LC). Dome-down LC creates a 360-degree view of the gallbladder-cystic duct junction, reducing the risk for anatomy misidentification. In addition, ultrasonic instrumentation eliminates the risk for electrocautery injuries. This study assessed the feasibility ...
متن کاملDissection by Ultrasonic Energy Versus Monopolar Electrosurgical Energy in Laparoscopic Cholecystectomy
INTRODUCTION Laparoscopic cholecystectomy is the gold standard for management of symptomatic gallstones. Electrocautery remains the main energy form used during laparoscopic dissection. However, due to its risks, search is continuous for safer and more efficient forms of energy. This review assesses the effects of dissection using ultrasonic energy compared with monopolar electrocautery during ...
متن کاملThe analysis of 146 patients with difficult laparoscopic cholecystectomy.
INTRODUCTION Laparoscopic cholecystectomy (LC) is very commonly performed surgical intervention. Acute or chronic cholecystitis, adhesions due to previous upper abdomen surgeries, Mirrizi's syndrome and obesity are common clinical conditions that can be associated with difficult cholecystectomy. In this study, we evaluated and scored the patients with difficult surgical exploration during lapar...
متن کاملRobotic Cholecystectomy Using the Newly Developed Korean Robotic Surgical System, Revo-i: A Preclinical Experiment in a Porcine Model
One Korean company recently successfully produced a robotic surgical system prototype called Revo-i (MSR-5000). We, therefore, conducted a preclinical study for robotic cholecystectomy using Revo-i, and this is a report of the first case of robotic cholecystectomy performed using the Revo-i system in a preclinical porcine model. Revo-i consists of a surgeon console (MSRC-5000), operation cart (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Canadian journal of surgery. Journal canadien de chirurgie
دوره 55 5 شماره
صفحات -
تاریخ انتشار 2012