Noninvasive assessment of coronary stents in patients by 16-slice computed tomography.
نویسندگان
چکیده
BACKGROUND The usefulness of thin-slice multi-detector computed tomography (MDCT) has been highly expected to assess the lumens of coronary artery stents. We evaluated the usefulness of 16-slice MDCT to assess the in-stent lumen after coronary artery stenting. METHODS In 42 consecutive patients after coronary artery stenting, retrospective ECG-gated CT-angiography using 16-slice MDCT (0.5-s rotation time, 16x0.625-mm detector collimation) was performed. The qualitative assessability of the lumens of 61 coronary stents (14 different types) by MDCT and the reasons for non-assessability were investigated. Furthermore, the evaluation of in-stent restenosis in 21 assessable stents of 16 patients, including quantitative density analysis by MDCT, was performed and the results were compared with those of conventional coronary angiography (CAG). RESULTS Of 61 stents, 42 (68.9%) were assessable. The assessability of diameter > or =3.5-mm stents made of stainless steel or cobalt was high (88.6%, 31/35), that of 3.0-mm stents was low (57.9%, 11/19) and all 2.5-mm stents were non-assessable due to partial volume effects and metal artifacts of stents. The lumens of stents made of tantalum were totally obscured and the metal artifacts of Bestent2 (gold markers) and S670 were severer than others. All non-assessable stents due to banding artifact and calcification were implanted in segment #1-3 and #6, respectively. In comparison to CAG, MDCT correctly detected the 5 in-stent restenoses and identified absence of restenoses was influenced strongly by the stent strut. CONCLUSION Despite some limitations, 16-slice MSCT is sufficiently useful for assessment of various coronary stents in patients and can detect in-stent restenoses of assessable stents with high accuracy in comparison to CAG.
منابع مشابه
Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study
Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...
متن کاملComparison of 16-slice computed tomography with conventional angiography to evaluate coronary artery stent patency.
OBJECTIVE In this study, we evaluated the utility of 16-slice MDCT (multidetector computed tomography) to assess stent patency after coronary artery stenting. MATERIALS AND METHODS Retrospective ECG-gated CT-angiography using 16-slice MDCT was performed in 52 consecutive patients with coronary artery stents. Qualitative assessment of 61 coronary stent lumens by MDCT is reported, and the reaso...
متن کاملAssessment of coronary artery stents by 16 slice computed tomography.
OBJECTIVE To analyse coronary stents with multislice spiral computed tomography (MSCT) in comparison with coronary angiography. PATIENTS AND METHODS 310 patients referred for conventional coronary angiography underwent MSCT on the next day (16 x 0.75 mm cross section, 420 ms rotation, 110 ml contrast agent intravenously at 4 ml/s). Two independent blinded reviewers analysed the MSCT. RESULT...
متن کاملCARDIOVASCULAR MEDICINE Assessment of coronary artery stents by 16 slice computed tomography
Objective: To analyse coronary stents with multislice spiral computed tomography (MSCT) in comparison with coronary angiography. Patients and methods: 310 patients referred for conventional coronary angiography underwent MSCT on the next day (16 60.75 mm cross section, 420 ms rotation, 110 ml contrast agent intravenously at 4 ml/ s). Two independent blinded reviewers analysed the MSCT. Results:...
متن کاملUsefulness of 64-slice multislice computed tomography coronary angiography to assess in-stent restenosis.
OBJECTIVES This study sought to evaluate the diagnostic accuracy of 64-slice multislice computed tomography (MSCT) coronary angiography in the follow-up of patients with previous coronary stent implantation. BACKGROUND Recent investigations have shown increased image quality and diagnostic accuracy for noninvasive coronary angiography with 64-slice MSCT as compared with previous-generation MS...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- International journal of cardiology
دوره 109 2 شماره
صفحات -
تاریخ انتشار 2006