Component position alignment with patient-specific jigs in total knee arthroplasty.

نویسندگان

  • Terence R Moopanar
  • Jeevaka E Amaranath
  • Rami M Sorial
چکیده

BACKGROUND The failure to restore mechanical alignment and appropriate rotational axis intraoperatively has been described as one of the most common causes of implant failure in total knee arthroplasty (TKA). Both conventional and computer-assisted TKA have their limitations. Patient-specific jigs (PSJ) offer a possible alternative method for TKA. The aim of this study was to investigate if the use of PSJ offers reproducible and accurate orientation of the components in TKA compared with conventional and computer-assisted surgery. METHODS We conducted a prospective case series looking at 261 consecutive patients undergoing TKA for osteoarthritis using the Signature Patient Specific System (Biomet, North Ryde, NSW, Australia). Each patient underwent a preoperative magnetic resonance imaging for planning. Using a computer software program, specialized femoral and tibial pin placement jigs were generated. Post-operative femoral and tibial component alignment was measured using computed tomography. RESULTS Of patients, 96.2% achieved femoral rotational alignment ±3 degrees of the transepicondylar axis. Tibial coronal alignment showed 92.7% of cases were 90 ± 3 degrees to the tibial medullary axis. Implant measurements of the posterior tibial slope demonstrated 76.6% of cases were within our accepted 0 to 7 degrees slope and 81.2% of patients had an overall mechanical axis within ±3 degrees of neutral. We also recorded femoral coronal alignment of the last 98 patients of our group and found that 99% were within 90 ± 3 degrees. CONCLUSION PSJ for TKA shows good accuracy in alignment when compared with conventional TKA. However, improvements in the development of the tibial alignment cutting guides will aid in further increasing its overall accuracy and reproducibility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty

Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...

متن کامل

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

The Effect of Total Knee Arthroplasty on Hindfoot Alignment in Patients with Severe Genu Varum and Genu Valgum

Background: The maintenance of deformity in the ankle and hindfoot after correction of knee deformity following kneearthroplasty may cause abnormal tension in the knee and patient dissatisfaction. The aim of this study was to determinethe effect of knee arthroplasty on the hindfoot alignment in patients with severe genu varum and valgum.Methods: A total of 84 patients with pri...

متن کامل

Patient-specific instrumentation for total knee replacement verified by computer navigation: a case report.

Patient-specific instrumentation (PSI) enables better restoration of the mechanical axis in total knee replacement (TKR) than conventional instrumentation (alignment guides) does. We verified the accuracy of the PSI by computer navigation. The PSI jigs were accurate only if they were pinned accurately onto the distal femur and proximal tibia. Any slight malposition of the jigs leads to malalign...

متن کامل

Restoration of the Mechanical Axis in Total Knee Artrhoplasty Using Patient-Matched Technology Cutting Blocks. A Retrospective Study of 132 Cases

Background: The aim of this study is to evaluate the accuracy of bone cuts and the resultant alignment, using theMyKnee patient specific cutting blocks.Methods: We retrospectively reviewed 132 patients undergoing primary TKR for osteoarthritis by one single surgeon.The operative time, the preoperative Hip-Knee-Ankle (HKA) axis based on the CT-scan, the postoperative HKA axisbased on long axis s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • ANZ journal of surgery

دوره 84 9  شماره 

صفحات  -

تاریخ انتشار 2014