CFD analysis of single-phase flows inside helically coiled tubes

نویسندگان

  • J. S. Jayakumar
  • S. M. Mahajani
  • J. C. Mandal
  • Kannan N. Iyer
  • P. K. Vijayan
چکیده

It has been well established that heat transfer in a helical coil is higher than that in a corresponding straight pipe. However, the detailed characteristics of fluid flow and heat transfer inside helical coil is not available from the present literature. This paper brings out clearly the variation of local Nusselt number along the length and circumference at the wall of a helical pipe. Movement of fluid particles in a helical pipe has been traced. CFD simulations are carried out for vertically oriented helical coils by

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of convective heat transfer of turbulent nanofluid flow through helical and conical coiled tubes

Application of nanofluid and coiled tubes are two passive methods for increasing the heat transfer. In the present study, the turbulent flows of water and nanofluid in coiled tubes heat exchanger were numerically studied. CuO-water nanofluid containing 1 vol% copper oxide nanoparticles was used and single-phase approach was considered for nanofluid flow. The effect of different geometrical para...

متن کامل

Effect of Inserting Coiled Wires in Tubes on the Fluid Flow and Heat Transfer Performance of Nanofluids

In the present study, numerical study of Al2O3-water nanofluid flow in different coiled wire inserted tubes are performed to investigate the effects of inserting coiled wires in tubes on the fluid dynamic and heat transfer performance ofv nanofluids. The numerical simulations of nanofluids are performed using two phase mixture model. The flow regime and the wall boundary conditions are assumed ...

متن کامل

Experimental and CFD Study of the Tube Configuration Effect on the Shell-Side Thermal Performance in a Shell and Helically Coiled Tube Heat Exchanger

"> Despite numerous studies of shell and helically coiled tube heat exchangers, a few investigations on the heat transfer and flow characteristic consider the geometrical <span style="font-size: 9pt; col...

متن کامل

Numerical Comparison of Turbulent Heat Transfer and Flow Characteristics of SiO2/Water Nanofluid within Helically Corrugated Tubes and Plain Tube

Turbulent heat transfer in Helically Corrugated Tubes (HCT) was numerically investigated for pure water and SiO2 nanofluid using Computational Fluid Dynamics (CFD). This study was carried out for different corrugating pitches (5, 7, 8 mm) and heights (0.5, 0.75, 1.25 mm) at various Reynolds numbers ranging from 5000 to 13300. The effect of nanoparticles on heat transfer augmentation for plain t...

متن کامل

Numerical Analysis of a Helical Coiled Heat Exchanger using CFD

Heat exchangers are the important equipments with a variety of industrial applications including power plants, chemical, refrigeration and air conditioning industries. Helically coiled heat exchangers are used in order to obtain a large heat transfer area per unit volume and to enhance the heat transfer coefficient on the inside surface. This paper deals with the CFD simulation of helical coile...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computers & Chemical Engineering

دوره 34  شماره 

صفحات  -

تاریخ انتشار 2010