Fast dynamic fat-water separation using shorter spatial-spectral excitation and novel temporal acquisition

نویسندگان

  • J. Yuan
  • T-C. Chao
  • R. S. Ababneh
  • Y. Tang
  • L. P. Panych
  • B. Madore
چکیده

Introduction: Many dynamic applications can benefit from reliable fat-water separation. Examples include temperature monitoring for ablation therapy (where fat signals can corrupt temperature measurements) and cardiac imaging (where fat infiltrations can indicate disease). Spectral-spatial pulses (SPSP) [1] are a common way of exciting only the water or fat content of an imaged slice or volume. However, the duration of SPSP pulses may be as much as 10 ms or more, making them impractical for short-TR sequences. Furthermore, their fat-water separation properties may be degraded by B0 inhomogeneities. A different fat-water separation technique, related to the UNFOLD temporal strategy [2], is combined here with a SPSP pulse for added performance. The duration of our SPSP pulse was reduced to only about 2 ms, making it readily compatible with most short TR/TE sequences. Fat signals imperfectly suppressed by the short pulse were further suppressed by the temporal strategy. The resulting hybrid approach should outperform SPSP pulses in the presence of field inhomogeneities and/or in cases where pulse duration must be significantly reduced, and outperform the temporal scheme from when very dynamic motion is present. Methods and Results: The SPSP pulse was designed using a 2DRF pulse library [www.ncigt.org]. TE was made to vary by ΔTE with a periodicity of 4 frames [0, 0.8ms, 0, 0.4ms] while TR was kept constant. Due to the offset frequency of fat (Δf), the ΔTE variations induced periodical phase variations of 2πΔfΔTE(t) in the fat signal. These phase variations acted as a ‘fingerprint’ in identifying fat signal through temporal processing. Following an FFT along the time axis, fat signals were identified using an approach closely related to a matching pursuit algorithm [3]. The proposed strategy for fat-water separation was implemented on a SSFP sequence, and tested at 3T using a moving phantom and in vivo free-breathing abdominal imaging. For both phantom and abdominal imaging, a 3*680μs SPSP pulse was used. The phantom moved back-and-forth along the S/I direction over a range of 2 cm, with a periodicity of about 5s. The phantom’s motion is evidenced by the changes in radius for the fat compartment, which consisted of olive oil in a tapered bottle (see Fig. 1). Figure 1 shows the phase image for time frames 1-16. The phase variations through all frames are plotted in Fig. 2 for the two pixels highlighted in Fig. 1. Figure 3 compares images from a regular RF pulse (Fig. 3a), the SPSP pulse without the temporal scheme (Fig. 3b), the fat signal imperfectly suppressed by the SPSP pulse but identified as fat by the temporal scheme (Fig. 3c), and the final fat-suppressed result where both the

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid fat suppression in MRI of the breast with short binomial pulses.

PURPOSE To develop a faster method of fat suppression for use in dynamic contrast enhanced MRI of the breast. MATERIALS AND METHODS A method of fast fat suppression is presented using spatially nonselective rapid binomial pulses. In contrast to conventional binomial frequency-selective pulses, these short pulses are applied without interpulse delay, allowing for very rapid spectrally selectiv...

متن کامل

Balanced Binomial-Pulse Steady-State Free Precession (BP-SSFP) for fast, inherently fat suppressed, non-contrast enhanced angiography

Introduction: In balanced SSFP for angiography, blood and muscle are inherently differentiated via the T2/T1 contrast. Fat signal suppression, however, relies on contrast preparation or chemical shift manipulation. The disadvantages of the former include regular interruption of the steady state MR signal, and fat signal regrowth during data acquisition. The latter can be divided into multiple v...

متن کامل

Rapid Fat Suppressed Imaging: Application to the Cartilage and the Breast

Q. Peng, R. W. McColl, P. T. Weatherall Radiology, UT Health Science Center at San Antonio, San Antonio, TX, United States, Radiology, UT Southwestern Medical Center, Dallas, TX, United States INTRODUCTION Fat suppression is an important MRI procedure widely employed in many research and clinical applications. Fat suppression reduces chemical shift artifacts, enhances lesion conspicuity, and im...

متن کامل

Compressive Chemical-Shift-Based Rapid Fat/Water Imaging

Introduction: Chemical-shift based fat and water separation techniques [1,2] are very common in practice and are effective in revealing important clinical information. They require imaging at multiple echo times, which often results in additional scan time. As compressed sensing (CS) [3-5] acceleration techniques become more available, it is necessary to be able to separate between fat and wate...

متن کامل

Spiral phase velocity mapping of left and right coronary artery blood flow: correction for through-plane motion using selective fat-only excitation.

PURPOSE To develop a method of correcting both right and left coronary artery flow velocities for the through-plane motion of the vessel, in order to allow details in the temporal flow profiles to be viewed. MATERIALS AND METHODS The methods developed use selective excitation and velocity mapping of the epicardial fat surrounding the artery, either in a separate acquisition (temporal resoluti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008