Flow injection potentiometry for enzymatic assay of cholesterol with a tungsten electrode sensor.

نویسندگان

  • M Situmorang
  • P W Alexander
  • D B Hibbert
چکیده

Flow injection potentiometry (FIP) for the enzymatic determination of cholesterol is reported. The assay utilises a combination of three enzymes: cholesterol esterase (CE), cholesterol oxidase (COD) and peroxidase (POD). The method is developed by the use of a tungsten wire electrode as a sensor vs. Ag/AgCl in conjunction with a redox mediator ferrocyanide. CE converts esterified cholesterol to free cholesterol, which is then oxidised by COD with hydrogen peroxide as product. Ferrocyanide is converted to ferricyanide by hydrogen peroxide, catalysed by POD, and the tungsten electrode responds to the ratio of ferricyanide to ferrocyanide. Flow injection potentiometry gave well-defined peaks for cholesterol samples with a fast response (30 s). Linear calibration was obtained from 0.05 to 3.0 mM cholesterol, with a slope of 60.2 mV/decade change in cholesterol concentration, and detection limit 0.01 mM cholesterol (S/N=3). Repeatability was 3% (CV). Interferences from commonly found species were shown to be negligible. The sensor cell is simple to construct, and it was free from surface contamination problems over long periods of use. The application of the sensor for the determination of serum cholesterol was demonstrated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Specific Fast Response CH4 Gas Sensor Based on Metal Oxide, Tungsten Carbide /SnO2Core-Shell Modified Interdigitated Electrode

In this study, a specific CH4 sensor is fabricated based on interdigitated electrode that modified with core-shell of tungsten carbide/tin oxide (WC/SnO2) nanoparticles by wet chemical method in different percents of carbon and tungsten. The morphology of wet chemical-synthesized WC/SnO2 core-shell was evaluated by different methods such as patterned X-ray d...

متن کامل

An electrode immobilized in a graphite matrix with ion pair complex for the determination of diclofenac in pharmaceuticals

A simple, precise, rapid and low-cost potentiometric method for diclofenac determination in pharmaceuticals is proposed. A new diclofenac-sensitive electrode was constructed by incorporating the diclofenac ion pair complex with butyl rhodamine B into graphite matrix. The electrode exhibited a linear response over the concentration range of 1 × 10-4 – 5 × 10-2 mol L-1, a detection limit of 3.9×1...

متن کامل

Determination of Magnesium (II) by a Coated Graphite Electrode Based on Risperidone as an Ionophore

In this research, a coated graphite electrode was constructed for determination of Mg2+ in pharmaceutical supplements. The designed sensor demonstrates an ideal Nernstian slope (30.1 mV. Decade-1) over a wide concentration range (1×10-6- 1×10-1 Mol L-1). The selectivity of the sensor was evaluated over 16 different cations by matched potential method and no serious interference was observed fro...

متن کامل

New Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ions

A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...

متن کامل

Polymeric Membrane Sensor for Potentiometric Determination of Tin(II) Ions

Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Talanta

دوره 49 3  شماره 

صفحات  -

تاریخ انتشار 1999