High speed microtribology with quartz crystal resonators.

نویسندگان

  • S Berg
  • D Johannsmann
چکیده

Quartz resonators in contact with metal-covered spheres have been used to study the tribology of micron-sized metal-metal contacts at high speed (1 m/sec and high frequency (12 MHz), while maintaining a shear amplitude in the nanometer range. The data aquisition is based on ring-down experiments, where the electrical excitation is periodically interrupted and the free decay of the oscillation is analyzed. At contact, an amplitude-dependent frequency and decay rate are found, indicative of an underlying nonlinear equation of motion. Using perturbation theory and the two-timing approximation, a nonlinear spring constant kappa(1)(x) and a nonlinear drag coefficient xi(1)(x) are explicitly derived. We find a local slip-to-stick-transition at a shear amplitude of 0.5 nm. Coating the gold sufaces with a self-assembled thiol monolayer removes the stick.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extraction of Nonlinear Thermo-Electroelastic Equations for High Frequency Vibrations of Piezoelectric Resonators with Initial Static Biases

In this paper, the general case of an anisotropic thermo-electro elastic body subjected to static biasing fields is considered. The biasing fields may be introduced by heat flux, body forces, external surface tractions, and electric fields. By introducing proper thermodynamic functions and employing variational principle for a thermo-electro elastic body, the nonlinear constitutive relations an...

متن کامل

Improvement of Sensor Sensitivity of Quartz Crystal Microbalance by Mechanical and Chemical Treatment∗

The influence of quartz plate roughening on the dynamic parameters of quartz resonators has been studied. For this aim AT-cut quartz plates with a diameter of 8 mm, after a standard technological cleaning, are subjected to treatment with abrasive of varying grain sizes: 3, 7, 14 and 20 μm. Piezoquartz resonators are fabricated on these plates with 4 mm Au electrodes. The alterations of resonato...

متن کامل

An Integrated Analysis of Vibrations of Quartz Crystal Plates with the Mindlin Plate Theory for Resonator Design and Optimization

The high frequency vibrations of quartz crystal plates have been extensively studied for the design and optimization of resonators which work at the thickness-shear vibration mode with relatively high frequency in the RF range. Earlier research work started from the development of special plate equations required for the high frequency vibrations of quartz crystal plates by Mindlin, known as th...

متن کامل

CMOS-Integrated Film Bulk Acoustic Resonators for Label-Free Biosensing

The throughput is an important parameter for label-free biosensors. Acoustic resonators like the quartz crystal microbalance have a low throughput because the number of sensors which can be used at the same time is limited. Here we present an array of 64 CMOS-integrated film bulk acoustic resonators. We compare the performance with surface plasmon resonance and the quartz crystal microbalance a...

متن کامل

Development of a Flow Injection Based High Frequency Dual Channel Quartz Crystal Microbalance

When the quartz crystal microbalance (QCM) is used in liquid for adsorption or desorption monitoring based bio- or chemical sensing applications, the frequency shift is not only determined by the surface mass change, but also by the change of liquid characteristics, such as density and viscosity, which are greatly affected by the liquid environmental temperature. A monolithic dual-channel QCM i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review letters

دوره 91 14  شماره 

صفحات  -

تاریخ انتشار 2003