Analysis and correction of spatial distortions produced by the gamma camera.

نویسنده

  • R R Perry
چکیده

Two types of distortions are produced by the gamma camera. One is nonuniform sensitivity re sponse over the detecting area. The second is spatial distortion; that is, the displacement from their true positions of the xand y-coordinates of a scintilla tion. This component of camera image distortion arises in the resolution and transfer of the xand y-coordinates of a scintillation and results in a non linear relationship between the object and the image. The existence of spatial distortions in cameraproduced radionuclide images is well known and has been recognized and observed by several workers (1-6). Today because of the present emphasis on com puter processing and analysis of the data image, gamma cameras are commonly interfaced to digital computers. This affords an opportunity to quantita tively analyze the inherent distortions introduced by the camera-computer system to any clinical image and to correct them by digital techniques. Nonuniform sensitivity of the camera system may be analyzed by uniformly irradiating the detecting crys tal and corrected by storing a digitized matrix of correction factors for subsequent application to any data matrix (7). Corrections for sensitivity distor tion are applied routinely to digitized images by some laboratories. However, spatial distortions produced by the gamma camera are not currently corrected. The purpose of this study is to determine and evalu ate the spatial distortions in radionuclide images caused by a gamma camera and to develop a method for routine correction of these errors by digital com putation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative assessment of the accuracy of maximum likelihood and correlated signal enhancement algorithm positioning methods in gamma camera with large square photomultiplier tubes

Introduction: The gamma cameras, based on scintillation crystal followed by an array of photomultiplier tubes (PMTs), play a crucial role in nuclear medicine. The use of square PMTs provides the minimum dead zones in the camera. The camera with square PMTs also reduces the number of PMTs relative to the detection area. Introduction of a positioning algorithm to improve the spat...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

Investigation of the effect of source distance and scattering medium on spatial resolution and contrast of Gamma camera images [Persian]

By identifying the effect of any parameter such as distance, attenuation and scattering on the Line Spread Function (LSF), one can compensate the quantitative and qualitative destructive effect of such parameters by deconvolution method. Using a 99mTC line source, this study was performed on a single head ADAC SPECT system operating in planar mode. Variation of FWTM and FWHM and LSFs as a...

متن کامل

An alternative mathematical modeling of the scintillation camera and framework for performance analysis of gamma-ray positioning algorithms

Introduction: Substantive amount of work has been done in modeling and analyzing the scintillation camera system processes including positioning and image formation. The goal of this work is to develop a framework for analyzing performance of nonlinear positioning methods upon construction of a mathematical model of the system. In this study, the photodetector array counts are ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 1972