A new LMS algorithm for analysis of atrial fibrillation signals
نویسندگان
چکیده
BACKGROUND A biomedical signal can be defined by its extrinsic features (x-axis and y-axis shift and scale) and intrinsic features (shape after normalization of extrinsic features). In this study, an LMS algorithm utilizing the method of differential steepest descent is developed, and is tested by normalization of extrinsic features in complex fractionated atrial electrograms (CFAE). METHOD Equations for normalization of x-axis and y-axis shift and scale are first derived. The algorithm is implemented for real-time analysis of CFAE acquired during atrial fibrillation (AF). Data was acquired at a 977 Hz sampling rate from 10 paroxysmal and 10 persistent AF patients undergoing clinical electrophysiologic study and catheter ablation therapy. Over 24 trials, normalization characteristics using the new algorithm with four weights were compared to the Widrow-Hoff LMS algorithm with four tapped delays. The time for convergence, and the mean squared error (MSE) after convergence, were compared. The new LMS algorithm was also applied to lead aVF of the electrocardiogram in one patient with longstanding persistent AF, to enhance the F wave and to monitor extrinsic changes in signal shape. The average waveform over a 25 s interval was used as a prototypical reference signal for matching with the aVF lead. RESULTS Based on the derivation equations, the y-shift and y-scale adjustments of the new LMS algorithm were shown to be equivalent to the scalar form of the Widrow-Hoff LMS algorithm. For x-shift and x-scale adjustments, rather than implementing a long tapped delay as in Widrow-Hoff LMS, the new method uses only two weights. After convergence, the MSE for matching paroxysmal CFAE averaged 0.46 ± 0.49 μV(2)/sample for the new LMS algorithm versus 0.72 ± 0.35 μV(2)/sample for Widrow-Hoff LMS. The MSE for matching persistent CFAE averaged 0.55 ± 0.95 μV(2)/sample for the new LMS algorithm versus 0.62 ± 0.55 μV(2)/sample for Widrow-Hoff LMS. There were no significant differences in estimation error for paroxysmal versus persistent data. From all trials, the mean convergence time was approximately 1 second for both algorithms. The new LMS algorithm was useful to enhance the electrocardiogram F wave by subtraction of an adaptively weighted prototypical reference signal from the aVF lead. The extrinsic weighting over 25 s demonstrated that time-varying functions such as patient respiration could be identified and monitored. CONCLUSIONS A new LMS algorithm was derived and used for normalization of the extrinsic features in CFAE and for electrocardiogram monitoring. The weighting at convergence provides an estimate of the degree of similarity between two signals in terms of x-axis and y-axis shift and scale. The algorithm is computationally efficient with low estimation error. Based on the results, proposed applications include monitoring of extrinsic and intrinsic features of repetitive patterns in CFAE, enhancement of the electrocardiogram F wave and monitoring of time-varying signal properties, and to quantitatively characterize mechanistic differences in paroxysmal versus persistent AF.
منابع مشابه
سنجش استعداد ابتلا به فیبریلاسیون دهلیزی با استفاده از تحلیلهای غیر خطی سیگنال الکتروکاردیوگرام
Atrial Fibrillation is a supra ventricular tachyarrhythmia, which is characterized by the deterioration of atrial mechanical function and aberrant. It has become a social and economic problem because a large percentage of the world population suffering from this disease. The early diagnosis of this fatal cardiac Arrhythmia can be prevented and managed it. In this study, we used non-invasive met...
متن کاملTranscranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve
Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...
متن کاملA Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures
Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...
متن کاملFrequency Estimation of Unbalanced Three-Phase Power System using a New LMS Algorithm
This paper presents a simple and easy implementable Least Mean Square (LMS) type approach for frequency estimation of three phase power system in an unbalanced condition. The proposed LMS type algorithm is based on a second order recursion for the complex voltage derived from Clarke's transformation which is proved in the paper. The proposed algorithm is real adaptive filter with real parameter...
متن کاملEffect of High Intensity Interval Training on the Level of Atrial Fibrillation, Fibroblast Growth Factor 23 and Klotho Protein in Male Rats with Renal Failure
Introduction: Cardiovascular problems and atrial fibrillation is one of the most prevalent secondary consequences in hemodialysis patients. This study aimed to examine the effect of high intensity interval training on the level of atrial fibrillation, fibroblast growth factor 23 and Klotho in male rats with chronic kidney disease. Methods: In this study, 30 male rats Wistar (7-8 weeks) were ra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2012