Influence of uncorrected ametropia on computer-based perimetry in patients with visual field defects and normal subjects
نویسندگان
چکیده
BACKGROUND During perimetric testing it is well known to wear spectacles. But less is known about to what extent refractive errors affect the response time performing computer-based visual tasks. METHODS Patients with visual field defects (VFD) (n = 6) and normal control subjects (n = 6) performed computer-based high resolution perimetry (HRP) with and without the use of spectacles. We recorded stimulus detection, response times, false hits, and fixation controls as well as contrast sensitivity with and without spectacles. RESULTS Performance without spectacles resulted in decreased contrast sensitivity of control subjects (41.5%, p < 0.05) and patients with VFD (36.4%, p < 0.05) and slowed reaction times from 436.2 ms to 463.7 ms in patients (p < 0.05) and from 371.3 ms to 402.3 ms in normal subjects (nonsignificant). In patients also reduced stimulus detection from 64.0% to 58.6% (nonsignificant) and increased number of false hits from 1.7 to 2.8% (nonsignificant) occurred. However, the normal subjects showed more false hits with glasses (2.3%) than without (1.0%, nonsignificant). The number of fixation control responses was unaffected. The majority of the subjects felt subjectively better wearing eyeglasses. CONCLUSION Both in normal subjects and patients with VFD computer-based diagnostic tests should always be performed with eyeglasses to optimize visual performance.
منابع مشابه
Automated static perimetry: the influence of myopic anisometropia on evaluation of visual field.
The aim of study was to establish which level of myopic refractive error influences visual field defects in automated static perimetry, if these defects are typical, and if optimal correction normalized the visual field. The study included 100 patients (200 eyes) divided into three groups according to the severity of the myopic refractive error: group A (till -3.25 Dsph), group B (-3.50 Dsph to...
متن کاملMotion automated perimetry identifies early glaucomatous field defects.
OBJECTIVE To determine if motion automated perimetry can identify early glaucomatous visual field defects in patients with suspected glaucoma (by disc), those with ocular hypertension, and those with primary open-angle glaucoma. METHODS Motion automated perimetry, a foveally centered motion test, and standard visual field tests were conducted on one randomly selected eye of normal patients (n...
متن کاملInvestigating the effects of glaucomatous (POAG) damage on the mVEP parameters
Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...
متن کاملTest-retest variability of frequency-doubling perimetry and conventional perimetry in glaucoma patients and normal subjects.
PURPOSE To compare the test-retest variability characteristics of frequency-doubling perimetry, a new perimetric test, with those of conventional perimetry in glaucoma patients and normal control subjects. METHODS The study sample contained 64 patients and 47 normal subjects aged 66.16+/-11.86 and 64.26+/-7.99 years (mean +/- SD), respectively. All subjects underwent frequency-doubling perime...
متن کاملUse of a portable head mounted perimetry system to assess bedside visual fields.
AIM This study was designed to test the ability of a portable computer driven, head mounted visual field testing system to perform automated perimetry on patients at their bedside and to compare these results with the "gold standard" for bedside examinations, confrontation visual fields. METHODS The Kasha visual field system is a portable automated perimeter which utilises a virtual reality h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 1 شماره
صفحات -