Clinical Application of the Threshold Equalizing Noise Test in Patients with Hearing Loss of Various Etiologies: A Preliminary Study

نویسندگان

  • Ho Yun Lee
  • Yu Mi Seo
  • Kyung Ae Kim
  • Yeon Shin Kang
  • Chin Saeng Cho
چکیده

BACKGROUND AND OBJECTIVES We aimed to make a preliminary assessment of the prevalence of cochlear dead regions (DRs) and the factors affecting the results of the threshold-equalizing noise (TEN) test in patients with hearing loss of various etiologies. SUBJECTS AND METHODS Between May and July 2014, 109 patients (191 ears) with hearing loss who visited our outpatient clinic were prospectively enrolled. Pure tone audiometry and TEN (HL) test were performed for all the patients. DR at each frequency was indicated by masked thresholds of ≥10 dB above the TEN level and ≥10 dB above the absolute threshold. RESULTS DR was present in 15.7% (n=30) of the 191 ears. According to disease entity, 16.6% of patients with sensorineural hearing loss had a DR. However, DR was absent in patients with chronic otitis media. According to audiometric configurations, DR was most common in moderately severe, flat hearing loss. Significantly worse hearing thresholds for both mean hearing level and hearing threshold at each frequency were found in the presence of DR (p<0.001). Logistic regression analysis showed that only the mean hearing level (odds ratio: 1.053, 95% confidence interval: 1.021-1.085) affected the presence of DR. CONCLUSIONS Although performance of the TEN test is limited by frequencies and hearing levels, it provides additional information regarding DRs and may therefore have the potential to be used as a prognostic tool for diverse diseases causing hearing loss.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noise pollution and hearing loss in one of the oil industries

Introduction: Nowadays, noise exposure is one of the most important industrial health problems. Noise exposure can cause hearing loss and many other health problems. So, paying attention to the noise exposure problem should be of main priority in industrial health programs. This study was conducted in an oil producing region, aimed to assess noise pollution and noise induced hearing loss. Met...

متن کامل

The Effect of Celecoxib, a Cyclooxygenase-2 Inhibitor on Noise- Induced Hearing Loss

Objective(s): Noise-induced hearing loss (NIHL) is the major cause of acquired hearing loss.  Celecoxib, a cyclooxygenase-2 (COX-2) inhibitor, is a non- steroidal anti- inflammatory drug (NSAID) with known antioxidant and antineoplastic activity. Therefore, we monitored the extent of temporary noise- induced threshold shifts (TTS) and cochlear damage caused by high level 4- kHz noise exposure t...

متن کامل

بررسی میزان افت شنوایی در کــــارگران واحد های صنعتی دارای آلودگی صوتی شهرستان زنجــان، سال 1381

Background: Noise as a harmful physical agent for factory workers is one of the most important causes of neurosensory hearing loss. In this study, workers of noise-polluted factories were assessed by audiometric equipment to determine their frequency and intensity of hearing loss (HL). Materials and Methods: In this descriptive study 2004 workers from five factories in Zanjan and suburbs (inclu...

متن کامل

Hearing loss among Fasa sugar factory workers’, Fars Provincre, Iran (2016)

Background: Hearing loss induced by noise is one of the well-known and main health problems of occupational exposures. As a result, the current study sought to examine the association between age, working experience, and smoking status and hearing loss among sugar factory workers. Materials and Methods: This cross-sectional study was conducted in 2016 among 270 workers of a sugar factory in Fa...

متن کامل

بررسی کاهش شنوایی شغلی آتش نشانان تهران

Hearing loss is a controversial occupational disease in fire fighters because exposure to hazardous levels of noise in this job is so variable and unpredictable. In this study, audiometric assessments were performed on 117 fire fighters to evaluate their hearing loss. The results showed that the average fire fighter has a characteristic noise-induced threshold shift, with maximum hearing loss o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2015