Uncertainty Analysis in Two-terminal Impedance Measurements with Residual Correction
نویسنده
چکیده
Residual impedance correction in impedance analyzers when using an asymmetrical test fixture needs three reference measurements, usually open circuit, short circuit, and load (meaning an impedance close to the impedance under test). This paper provides an uncertainty estimate for impedance measurements that apply a simple open/short correction in spite of using an asymmetrical test fixture. Experimental results show that the minimal uncertainty is obtained for impedance values close to the geometric mean of the short-circuit and open-circuit impedances, and that the theoretical prediction is indeed an upper limit for the actual uncertainty.
منابع مشابه
A novel bi-objective reliable location routing model considering impedance function under demand-side and supply-side uncertainty (A Case study)
Reliable location routing problem considers a location problem and a vehicle routing problem in order to select the optimal location of facilities and at the same time the optimal routes for vehicles considering the unexpected failure for facilities in which, all facilities may fail with a probability. In this paper, a bi-objective mathematical model has been developed to minimize the total cos...
متن کاملElectrical conductivity measurement of metal plates using broadband eddy-current and four-point methods
Electrical conductivity of metal plates is measured by two distinct methods and the uncertainty associated with each method is evaluated. First, the impedance of an air-cored eddy-current coil is measured in the frequency range 100 Hz to 20 kHz. Corrections are made to account for the fact that the coil is not a pure inductor but exhibits finite resistance and capacitance in and between the win...
متن کاملUncertainty analysis for four terminal-pair capacitance and dissipation factor characterization at 1 and 10 MHz
The Electricity Division at the Nationals Institute of Standards and Technology (NIST, formerly NBS) has developed the capability to characterize capacitance and dissipation factor for four terminal-pair (4TP) air dielectric capacitors at frequencies from 1 kHz to 10 MHz. The method, based on work by Cutkosy and Jones of NBS and recent developments by Hewlett-Packard Japan, involves single-port...
متن کاملBernoulli collocation method with residual correction for solving integral-algebraic equations
The principal aim of this paper is to serve the numerical solution of an integral-algebraic equation (IAE) by using the Bernoulli polynomials and the residual correction method. After implementation of our scheme, the main problem would be transformed into a system of algebraic equations such that its solutions are the unknown Bernoulli coefficients. This method gives an analytic solution when ...
متن کاملPhase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis
Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...
متن کامل