Esophageal self-expanding metallic stent (SEMS) migration: it's a topsy-turvy world.
نویسندگان
چکیده
A 47-year-old woman underwent endoscopic treatment of a fistula following sleeve gastrectomy, performed 3 weeks earlier. A partially covered self-expandable metallic stent (SEMS) was inserted (15cm, 18–23mm Ultraflex, Boston Scientific, Natick, Massachusetts, USA). At 1 month follow-up she was symptomfree. Radiographic examination and computed tomography (●" Fig.1) showed that the stent had partially migrated distally, and there was no collection. The patient became aphagic 6 days before her scheduled admission for retrieval of the partially covered SEMS.Endoscopy revealed that the stent had bent and “re-migrated” proximally, into the mid-esophagus, thus causing complete obstruction (●" Fig.2). The stent was retrieved using rat-tooth forceps, and the patient was discharged the next day. She remains symptom-free. Leaks complicate bariatric surgery in 2.4%–4.9% of cases [1–3]. Endoscopic placement of self-expandable stents is a well-recognized part of leak management and leads to successful closure in 87.7% [4]. Among the most frequent complications of SEMS insertion is stent migration (11.1%) and stenosis caused by hyperplasia (11.1%) [5]. This rate of migration is related to the design of the stents, which is based on their use in stricture management. In the absence of stenosis, the incomplete contact between the mucosa and the stent may lead to migration. Hyperplasia following insertion of partially covered SEMS helps to decrease the risk of migration [4]. In the present case, we found a stent folded onto itself in the esophagus, and radiographs showed that the upper part of the stent was located distally. We speculate that after the stent migrated into the gastric sleeve (●" Fig.3), it was partially repositioned nearly horizontally, after which it folded onto itself and migrated proximally into the esophagus, where it caused complete obstruction. This may be explained by narrowing of the gastric body following the sleeve, which could hinder distal migration in the antrum.
منابع مشابه
Tracheal Penetration and Tracheoesophageal Fistula Caused by an Esophageal Self-Expanding Metallic Stent
Tracheal penetration of esophageal self-expanding metallic stents (SEMS) with/without tracheoesophageal fistula (TEF) formation is a rare occurrence. We report the case of a 66-year-old female patient with advanced esophageal squamous cell carcinoma who had undergone palliative esophageal stenting on three occasions for recurrent esophageal stent obstruction. On evaluation of symptoms of breath...
متن کاملEffect of a paclitaxel-eluting metallic stent on rabbit esophagus
The use of self-expanding metallic stents (SEMS) is the current treatment of choice for malignant gastrointestinal obstructions. A paclitaxel-eluting metallic SEMS (PEMS) may have an antitumor effect on esophageal tissue. PEMS with 10% paclitaxel or conventional SEMS were inserted into the lower esophagus of rabbits. Following the insertion of the stents for 1, 2, 4 and 6 weeks, the rabbits wer...
متن کاملSelf-expanding covered metallic stent as a bridge to surgery in esophageal cancer: impact on oncologic outcomes.
BACKGROUND Self-expanding metallic stents (SEMSs) have been used as a bridge to surgery, relieving dysphagia and maintaining nutrition, in patients with operable but obstructive esophageal cancer (EC). However, the impact of SEMSs on oncologic outcomes is unknown. The aim of this study was to evaluate the impact of SEMS insertion before EC surgery on oncologic outcomes. STUDY DESIGN From 2000...
متن کاملPlastic and Biodegradable Stents for Complex and Refractory Benign Esophageal Strictures
Endoscopic stent placement is a well-accepted and effective alternative treatment modality for complex and refractory esophageal strictures. Among the currently available types of stents, the partially covered self-expanding metal stent (SEMS) has a firm anchoring effect, preventing stent migration and ensuring effective covering of a narrowed segment. However, hyperplastic tissue reaction driv...
متن کاملRedeployment of proximally misplaced self-expandable metallic stent in an inoperable esophageal carcinoma, using an overtube technique.
Placement of self-expandable metallic stents (SEMSs) has been demonstrated to be a safe palliative procedure for patients with inoperable esophageal cancer and dysphagia [1,2]. When deployed distally from the stricture, most SEMSs can be repositioned endoscopically by pulling the lasso attached to the proximal end of the SEMS. However, if the deployment of the SEMS is completely proximal from t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Endoscopy
دوره 44 Suppl 2 UCTN شماره
صفحات -
تاریخ انتشار 2012