A simple, selective, precise and stability-indicating high-performance thin layer chromatographic method of analysis of meloxicam both as a bulk drug and in formulation has been developed. The mobile phase selected was ethyl acetate:cyclohexane:glacial acetic acid (6.5:3.5:0.02% v/v/v). The calibration curve of the drug was linear in the range of 100-500 ng. The spectrodensitometric analysis was carried out in the absorbance mode at 353 nm. The mean (±RSD) values of slope, correlation coefficient and intercept were 3183.8±0.358, 0.9996±0.0321 and 13012±7.1 respectively. The system precision and the method precision studies were carried out with RSD of 0.83 and 1.89 respectively. The limit of detection and quantitation were 30 ng and 99 ng respectively. The mean percent recovery was found to be 100.3%. The method was used to analyze meloxicam from marketed tablet formulation in the presence of commonly used excipients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stress Studies of Tenofovir Disoproxil Fumarate by HPTLC in Bulk Drug and Pharmaceutical Formulation

A stability-indicating high-performance thin-layer chromatographic (HPTLC) method for determination of tenofovir disoproxil fumarate in bulk drug and in tablet has been developed and validated. The mobile phase selected was chloroform:methanol (9.0:1.0, v/v) with ultraviolet (UV) detection at 260 nm. The retention factor was found to be 0.49 ± 0.03 with correlation coefficients of 0.9994 in the...

متن کامل

TLC determination of meloxicam in tablets and after acidic and alkaline hydrolysis.

A simple and rapid method for separation and determination of meloxicam and its degradation products by thin-layer chromatography with densitometric detection in pharmaceutical preparations was described. The method employed TLC F254 plates as the stationary phase. The solvent system consisted of ethyl acetate : toluene : butylamine (2:2:1, v/v/v). Densitometric analysis was carried out in abso...

متن کامل

Stability indicating HPTLC determination of pimozide in bulk and pharmaceutical dosage form

A simple, selective, precise and stability indicating high-performance liquid chromatographic method was developed and validated for the determination of pimozide in bulk and pharmaceutical dosage form. The method employed aluminium plates precoated with silica gel 60F-254 as the stationary phase. The solvent system consisted of toluene:acetone:ammonia (5:5:0.1 v/v/v). Compact spot was observed...

متن کامل

Stability indicating HPTLC method for determination of terbutaline sulfate in bulk and from submicronized dry powder inhalers.

A stability-indicating high-performance thin-layer chromatographic (HPTLC) method has been developed for the determination of terbutaline sulfate (TBS) as a bulk drug and in pharmaceutical formulations (submicronized dry powder inhalers). The separation was achieved on TLC aluminum plates precoated with silica gel 60F-254 using chloroform-methanol (9.0:1.0 v/v) as mobile phase. The densitometri...

متن کامل

HPTLC-densitometry method development and validation for simultaneous determination of abacavir, lamivudine and zidovudine in combined dosage form

A simple, accurate and precise HPTLC- densitometry method for the simultaneousdetermination of abacavir, lamivudine and zidovudine in pharmaceutical tablet has beendeveloped. Separation of tablet components was performed on aluminum backed HPTLC plates(silica gel 60 F254 20×20 cm with 0.2 mm thickness, Camag, Muttenz, Switzerland ) usingmethanol : chloroform : acetonitrile (4 : 8 : 3 v/v). Good...