Pressures in critical regions of the below-knee patellar-tendon-bearing prosthesis.
نویسندگان
چکیده
In a biomechanical analysis of the forces transmitted to an amputated limb by a below-knee patellar-tendon-bearing prosthesis, R@di% (1) showed in 1962 that the principal forces occur in the patellar ten bn, the distal anterior tibial, the latera tibial condylar, and the medial tibial condylar regions. Apparantly the design of this prosthesis was such that the forces were directed to those areas in order to transmit them as effectively as possible to the musculo-skeletal system, by a direct route through tissues that could withstand the pressures generated, and to provide continuous control of balance and stability. In the investigation of prosthesis-limb interface pressures of the aboveknee prosthesis in 1967, Appoldt and Bennett (2) found the mean brim load while standing to be roughly 40 percent of the maximum load developed in walking. Similar reductions occurred at other sample sites.
منابع مشابه
Development of Refined Fitting Procedures for Lower-extremity Prosthese
With the development of the patellar-tendon-bearing prosthesis by the University of California at Berkeley, many new advantages in simplicity, comfort, and function were available to the below-knee amputee. However, there still exists the problem of concentrated pressures over small areas of the stump. The original design of the patellar-tendonbearing prosthesis was intended to distribute the l...
متن کاملApplication of prosthetics-orthotics principles to treatment of fractures.
1 School of Medicine, University of Miami, Jackson Memorial Hospital, Miami, Fla. 33152. Greater knowledge and understanding of bioengineering by the prosthetics and orthotics industries during the past twenty years have resulted in the development of highly functional and sophisticated appliances. For example, modern prostheses for lowerand upperextremity amputees are now designed with proper ...
متن کاملThe evolution of functional bracing of fractures.
©2006 British Editorial Society of Bone and Joint Surgery doi:10.1302/0301-620X.88B2. 16381 $2.00 J Bone Joint Surg [Br] 2006;88-B:141-8. Functional fracture bracing, described in 1967, 1 was inspired by the patellar-tendonbearing prosthesis which had recently been developed for below-knee amputees. This prosthesis had eliminated the traditional thigh corset and allowed the transfer of weight-b...
متن کاملAnalysis of a below-knee patellar tendon-bearing prosthesis: a finite element study.
In this study, a finite element (FE) model of a below-knee prosthesis of patellar tendon-bearing (PTB) design, and several altered variations of the model have been constructed. A load of approximately 1.5 times normal body weight (984 N) was applied at the heel of the model to simulate heelstrike conditions. The "base" model was then analyzed and revised iteratively until a model which provide...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Bulletin of prosthetics research
دوره 10 19 شماره
صفحات -
تاریخ انتشار 1973