Ferroresonance in Power and Instrument Transformers
نویسندگان
چکیده
This chapter describes the fundamental concepts of ferroresonance phenomenon and analyzes its symptoms and the consequences in transformers and power systems. Due to its nonlinear nature, the ferroresonance phenomenon can result in multiple oscillating modes which can be characterized based on the concepts of the nonlinear dynamic systems, e.g., Poincare map. Among numerous system configurations which can experience the phenomena, a few typical systems scenarios, which cover the majority of the observed ferroresonance incidents in power systems, are introduced. This chapter also classifies the ferroresonance study methods into the analytical and the time-domain simulation approaches. A set of analytical approaches are presented, and the corresponding fundamentals, assumptions, and limitations are discussed. Furthermore, key parameters for accurate digital time-domain simulation of the ferroresonance phenomenon are introduced, and the impact of transformer models and the iron core representations on the ferroresonance behavior of transformers is investigated. The chapter also presents some of the ferroresonance mitigation approaches in power and instrument transformers. DOI: 10.4018/978-1-4666-1921-0.ch005
منابع مشابه
Impacts of New Suggested Ferroresonance Limiter on the Stability Domain of Ferroresonance Modes in Power Transformers Considering Metal Oxide Surge Arrester Effect
this work studies the effect of neutral earth resistance on the controlling ferroresonance oscillation in the power transformer including MOV surge arrester. A simple case of ferroresonance circuit in a three phase transformer is used to show this phenomenon and the three-phase transformer core structures including nonlinear core losses are discussed. The effect of MOV surge arrester and neutra...
متن کاملFerroresonance Phenomenon in Power Transformers - Experimental Assessment
This paper reports on the results of recent research and development efforts to study and assess various impacts of ferroresonance phenomenon on operating performance of power transformers and to investigate ways to mitigate the effects of such phenomenon. Three-phase core-type transformers are used in the study. The results of the technical investigation and the associated ferroresonance exper...
متن کاملApplying Wavelet Transform to Ferroresonance Detection and Protection
Non-synchronous breakage or line failure in power systems with light or no loads can lead to core saturation in transformers or potential transformers. This can cause component and capacitance matching resulting in the formation of resonant circuits, which trigger ferroresonance. This study employed a wavelet transform for the detection of ferroresonance. Simulation results demonstrate the effi...
متن کاملApplication of PSCAD/EMTDC and Chaos Theory to Power System Ferroresonance Analysis
Ferroresonance is a nonlinear dynamic electrical phenomenon, which frequently occurs in a power system that comprises no-load saturable transformers, transmission lines (or cables) and single-phase switching with three-phase supply. Common characteristics of a nonlinear system are multiple equilibrium points, limit cycles, jump resonance and subharmonic generation. This paper presents an extens...
متن کاملFerroresonance in Three-phase Power Distribution Transformers: Sources, Consequences and Prevention
Ferroresonance is a phenomenon that involves high distorted levels of overvoltage and overcurrents. During the last decades, the three-phase ferroresonance research has suffered several changes due to the continuously changing equipment and network. This paper analyses every main factor that is somehow related with the origin, consequences and the preventive decisions that may lead us to avoid ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017