Microencapsulation to reduce mechanical loss of microspheres: implications in myocardial cell therapy.

نویسندگان

  • Adil H Al Kindi
  • Juan Francisco Asenjo
  • Yin Ge
  • Guang Yong Chen
  • Jasmine Bhathena
  • Ray C-J Chiu
  • Satya Prakash
  • Dominique Shum-Tim
چکیده

OBJECTIVE Previous regenerative studies have demonstrated massive cell losses after intramyocardial cellular delivery. Therefore, efforts at reducing mechanical losses may prove more successful in optimising cellular therapy. In this study, we hypothesized that escalating mesenchymal stem cells (MSCs) dose will not produce corresponding improvement in cardiac function due to washout of the small cells in microcirculation. Using microspheres similar in size to MSCs, that are encapsulated in alginate-poly-l-lysine-alginate (APA), we tested the hypothesis that size is an important factor in early losses. METHODS In experiment I, five groups of rats (n=9 each) underwent coronary ligation; group I had no treatment; the other groups received escalating 0.5 × 10(6), 1.5 × 10(6), 3 × 10(6) and 5 × 10(6) of MSCs each. Echocardiogram was performed at baseline, 2 days and 7 weeks after surgery. In experiment II, cell-sized microspheres (10 μm) were encapsulated in APA microcapsules. In group I (n=16), rats received bare microspheres, group II (n=16) microspheres within 200 μm microcapsules and in group III (n=16), microspheres within 400 μm microcapsules. After 20 min, hearts were quantified for the amount retained. RESULTS Myocardial function did not improve further with escalating cell doses beyond an initial response at 1.5 × 10(6) cells. Encapsulated microspheres in 200 μm and 400 μm microcapsules demonstrated a fourfold increase in retention rate compared with 10 μm microspheres. CONCLUSION We concluded that suboptimal functional improvement in this animal model starts at 1.5 × 10(6) cells and does not respond to escalating cell doses. Improving mechanical retention is possible by increasing the size of the injectate. Microencapsulation could be used to encapsulate donor cells and facilitate functional improvement in cellular heart failure therapy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Microencapsulation on Photo-Stability of Nifedipine

Nifedipine (NIF), a 1,4-dihydropyridine calcium channel antagonist, undergoes photo-degradation to dehydro-nifedipine (DNIF) upon exposure to ultraviolet (UV) light and to the nitroso analogue of dehydro-nifedipine (NDNIF) when exposed to sunlight or some kinds of artificial lights. NIF photo-degradation products do not contribute to clinical activity, thus prevention of photo-degradation of NI...

متن کامل

Chapter 2 Applications of Cell Microencapsulation

The goal of this chapter is to provide an overview of the different purposes for which the cell microencapsulation technology can be used. These include immunoisolation of non-autologous cells used for cell therapy; immobilization of cells for localized (targeted) delivery of therapeutic products to ablate, repair, or regenerate tissue; simultaneous delivery of multiple therapeutic agents in ce...

متن کامل

Effect of Microencapsulation on Photo-Stability of Nifedipine

Nifedipine (NIF), a 1,4-dihydropyridine calcium channel antagonist, undergoes photo-degradation to dehydro-nifedipine (DNIF) upon exposure to ultraviolet (UV) light and to the nitroso analogue of dehydro-nifedipine (NDNIF) when exposed to sunlight or some kinds of artificial lights. NIF photo-degradation products do not contribute to clinical activity, thus prevention of photo-degradation of NI...

متن کامل

Beating and arrested intramyocardial injections are associated with significant mechanical loss: implications for cardiac cell transplantation.

BACKGROUND Cellular cardiomyoplasty is emerging as a potentially novel therapeutic option for heart failure and typically involves direct intramyocardial injection of donor cells into a beating heart. Yet, limited rates of cell engraftment remain an obstacle to be overcome before cell therapy is fully recognized. Mechanical and biological mechanisms may account for observed donor cell loss. Thi...

متن کامل

Transplantation of Cardiogenic Pre-Differentiated Autologous Adipose-Derived Mesenchymal Stem Cells Induced by Mechanical Loading Improves Cardiac Function Following Acute Myocardial Infarction in Rabbit Model

Objective- Investigate myocardial performance after autologous adipose-derived (ASCs) mesenchymal stem cell differentiated under equiaxial cyclic strain, transplantation in rabbits with acute myocardial infarction (AMI). Design- Prospective, randomized experimental study Animals- 20 New Zealand White rabbits (2-3 kg) P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 39 2  شماره 

صفحات  -

تاریخ انتشار 2011