Primary frequency response from dynamically controlled refrigerators was investigated. A control algorithm was applied to a model of refrigerators to regulate their power consumption according to the deviation of system frequency. A model of a population of refrigerators equipped with such control was implemented in PowerFactory. A simplified Great Britain (GB) power system model was used to investigate primary frequency response from the refrigerators. Simulation results show that the refrigerators react effectively to the frequency variations by varying their power consumption.
منابع مشابه
Evolution of primary frequency control requirements in Great Britain with increasing wind generation
With the increase of renewable generating capacity following the ambitious targets set by many governments for the next decades, there will be major changes in power generation and challenges for balancing transmission grids. In particular, primary frequency control requirements will be increased following a potential reduction of system inertia. An assessment of the frequency response reserve ...
متن کاملFuzzy-Logic Based Frequency Controller for Wind Farms Augmented With Energy Storage and PV Systems
To improve the primary frequency response in future low-inertia hybrid power system a fuzzylogic based frequency controller (FFC) for wind farms augmented with energy storage systems(wind-storage system) and intelligent PV farms for the frequency stabilization is proposed inthis paper. Using system frequency deviations the proposed controller provides bidirectionalreal p...
متن کاملModeling the Frequency Response Movements in Power Transformers for Predicting Purposes
Power transformers are key components in electrical power supplies and their failure could cause severe consequences on continuity of service and also generates substantial costs. Identifying problems at an early stage, before catastrophic failure occurs, is a great benefit for reliable operation of power transformers. Frequency Response Analysis (FRA) is a new, well-known and powerful diagnost...
متن کاملResponses of primary somatosensory cortical neurons to controlled mechanical stimulation.
The results of psychophysical studies suggest that displacement velocity may contribute significantly to the sensation of subcortical somatosensory neurons. The cortical correlates of these phenomena, however, are not known. In the present study the responses of rapidly adapting (RA) neurons in the forelimb region of cat primary somatosensory cortex (SI) to controlled displacement of skin and h...
متن کاملModern power system frequency response evaluation with virtual power plant penetration
New power systems based on VPP will be expanded in the future and analysis of the frequency behavior of these systems compared to current systems in the field of disruptions will be one of the most important issues of the system operators. In this paper, the equations of the frequency response model of conventional power system are expanded by considering the VPP's and their effective component...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -