A digitizer with exceptional accuracy for use in prosthetics research: a technical note.

نویسندگان

  • Joan E Sanders
  • Stuart B Mitchell
  • Santosh G Zachariah
  • Kelvin Wu
چکیده

A mechanical digitizer was developed for use in prosthetics research where measurements of small differences in shape are of interest. Root-mean-square error was 0.075 mm in the radial direction, 0.05 degrees in the tangential direction, and 0.1 mm in the vertical direction. The system has potential use for time-dependent assessment of changes in socket and residuum cast shape, assessment of socket fabrication systems, and development of accurate prosthetic finite element models.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implant-Based Prosthetic Reconstruction in Patients with Congenital Ear Defects (Technical Note)

Background and aims: Loss of all or part of the ear is one of the significant defects in the head and neck area (regardless of the cause) that can result from trauma, cancer, congenital diseases, or surgery to remove benign tumors. These defects can be reconstructed with the help of surgical procedures or cosmetic prostheses. However, due to the complex structure of the ear, reconstructive surg...

متن کامل

Design of a 3-D surface scanner for lower limb prosthetics: a technical note.

A three-dimensional (3-D) noncontact optical surface range sensing imaging system that captures the entire circumferential and distal end surfaces of lower limb residua in less than 1 second has been developed. The optical surface scanner (OSS) consists of four charge injection device (CID) cameras and three white light projectors, mounted on a rigid frame surrounding the subject's residuum, al...

متن کامل

Integrated Approach for Cellular Manufacturing a Case Study (TECHNICAL NOTE)

To cope with fast changing customer requirements, industrial demands and to meet stringent specifications of customers Cellular Manufacturing Systems has become an effective tool in hands of manufacturers. Most of the published literature on cell formation earlier considers only the data available in the route sheets and ignored subproblems associated with cell formation. There is a need to dev...

متن کامل

The VA-Cyberware lower limb prosthetics-orthotics optical laser digitizer.

Characterization of the residual limbs and limb segments of patients for prosthesis and orthosis design has principally been a subjective process, highly dependent upon the skill, level of training, and experience of the prosthetist/orthotist involved. Even with the application of computer-aided design (CAD) and computer-aided manufacturing (CAM) technologies in prosthetics and orthotics, resid...

متن کامل

A New Hybrid Framework for Filter based Feature Selection using Information Gain and Symmetric Uncertainty (TECHNICAL NOTE)

Feature selection is a pre-processing technique used for eliminating the irrelevant and redundant features which results in enhancing the performance of the classifiers. When a dataset contains more irrelevant and redundant features, it fails to increase the accuracy and also reduces the performance of the classifiers. To avoid them, this paper presents a new hybrid feature selection method usi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 40 2  شماره 

صفحات  -

تاریخ انتشار 2003