Comparison of technetium-99m tetrofosmin and thallium-201 single-photon emission computed tomographic imaging for detection of myocardial perfusion defects in patients with coronary artery disease.

نویسندگان

  • H Shanoudy
  • P Raggi
  • G A Beller
  • A Soliman
  • E G Ammermann
  • R J Kastner
  • D D Watson
چکیده

OBJECTIVES We compared dipyridamole technetium-99m (Tc-99m) tetrofosmin and thallium-201 (Tl-201) single-photon emission computed tomographic (SPECT) imaging with respect to the detection rate of perfusion abnormalities in 26 patients with angiographic coronary artery disease (CAD). BACKGROUND Experimental studies have shown that myocardial extraction of Tc-99m tetrofosmin is lower than that of Tl-201 at high flow rates, resulting in less severe defects with vasodilator stress. It is uncertain whether this results in a lower sensitivity than Tl-201 for detecting coronary stenoses with vasodilator stress in patients. METHODS Twenty-six patients with CAD underwent both dipyridamole Tl-201 and Tc-99m tetrofosmin SPECT. Tomographic images were scored for initial defects and the presence of reversibility. Defect magnitude was computer quantitated. RESULTS Of the 26 patients, 25 had defects on both Tl-201 and Tc-99m tetrofosmin SPECT images. Of 340 segments analyzed, 102 had defects by Tl-201 and 92 by Tc-99m tetrofosmin (p = NS). Whereas Tl-201 detected 27 fixed defects in 12 patients, Tc-99m tetrofosmin identified 37 fixed defects in 14 patients (p = NS). In contrast, Tl-201 identified more reversible and partially reversible defects than did Tc-99m tetrofosmin (89 vs. 55, p = 0.002). The average defect magnitude (percent normal) was similar for defects concordantly graded as fixed (38 +/- 3.0% for Tl-201 vs. 42 +/- 4% [mean +/- SEM] for Tc-99m tetrofosmin, p = NS). The average defect magnitude for defects concordantly graded as completely reversible was significantly more severe on Tl-201 than on Tc-99m tetrofosmin (49 +/- 3% vs. 58 +/- 3%) SPECT images. A significantly greater defect magnitude for Tl-201 was also found for defects concordantly classified as partly reversible (30 +/- 4% for Tl-201 vs. 45 +/- 5% for Tc-99m tetrofosmin). CONCLUSIONS With dipyridamole stress, 1) at least one defect was seen on both Tl-201 and Tc-99m tetrofosmin SPECT images; 2) Tc-99m tetrofosmin SPECT identified fewer reversible defects than did Tl-201, but showed a similar number of fixed defects; 3) the magnitude of reversible defects seen on Tc-99m tetrofosmin images was less, whereas fixed defects were similar for both tracers; 4) reversible defects seen on Tl-201 and not on Tc-99m tetrofosmin SPECT images were predominantly regions perfused by mild coronary stenoses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of occult thymoma during exercise thallium 201, technetium 99m tetrofosmin imaging for coronary artery disease.

Thallium (Tl) 201 and technetium (Tc) 99m tetrofosmin single-photon emission CT are routinely used in the evaluation of coronary artery disease. Mediastinal tumors demonstrate Tl 201 and Tc 99m tetrofosmin uptake. We report a 56-year-old man who developed chest pain after a previously successful angioplasty and stent of the left anterior descending coronary artery. He underwent a Tl 201, Tc 99m...

متن کامل

Radiopharmaceutical agents for myocardial perfusion imaging.

Myocardial perfusion imaging (MPI) is a wellestablished noninvasive method of assessing coronary blood flow.1–5 MPI is capable of identifying regional abnormalities in coronary artery blood flow and determining their physiological relevance to myocardial function and viability. MPI requires the intravenous injection of a radioactive blood flow marker followed by imaging of regional myocardial u...

متن کامل

Comparison of 99mTc-N-DBODC5 and 99mTc-MIBI of Myocardial Perfusion Imaging for Diagnosis of Coronary Artery Disease

Despite recent advances in therapeutic and diagnostic approaches, coronary artery disease (CAD) and its related cardiac disorders represent the most common cause of death in the United States. Nuclear myocardial perfusion imaging (MPI) technologies play a pivotal role in the diagnosis and treatment design for CAD. Recently, in order to develop improved MPI agents for diagnosis of CAD, (99m)Tc-[...

متن کامل

Quantitative rest technetium-99m tetrofosmin imaging in predicting functional recovery after revascularization: comparison with rest-redistribution thallium-201.

OBJECTIVES This study was undertaken to 1) compare the regional myocardial tracer distributions between rest technetium (Tc)-99m tetrofosmin and rest-redistribution thallium (Tl)-201 images in patients with coronary artery disease and left ventricular dysfunction; and 2) assess the comparative values of these agents for predicting functional recovery after revascularization. BACKGROUND Tc-99m...

متن کامل

Functionally relevant coronary artery disease: comparison of 64-section CT angiography with myocardial perfusion SPECT.

PURPOSE To prospectively determine the accuracy of 64-section computed tomographic (CT) angiography for the depiction of coronary artery disease (CAD) that induces perfusion defects at myocardial perfusion imaging with single photon emission computed tomography (SPECT), by using myocardial perfusion imaging as the reference standard. MATERIALS AND METHODS All patients gave written informed co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 31 2  شماره 

صفحات  -