Diagnostic performance of multislice spiral computed tomography of coronary arteries as compared with conventional invasive coronary angiography: a meta-analysis.

نویسندگان

  • Michèle Hamon
  • Giuseppe G L Biondi-Zoccai
  • Patrizia Malagutti
  • Pierfrancesco Agostoni
  • Rémy Morello
  • Marco Valgimigli
  • Martial Hamon
چکیده

OBJECTIVES This study was designed to define the current role of multislice spiral computed tomography (MSCT) for the diagnosis of coronary artery disease (CAD) using a meta-analytic process. BACKGROUND Multislice spiral computed tomography has recently been proposed as an alternative to conventional coronary angiography (CA) for the diagnosis of CAD. METHODS Using Medline, we identified 29 studies (2,024 patients) evaluating CAD by means of both MSCT (> or =16 slices) and conventional CA before July 2006. After data extraction the analysis was performed according to a random-effects model. RESULTS The per-segment analysis pooled the results from 27 studies corresponding to a cumulative number of 22,798 segments. Among unassessable segments, 4.2% were excluded from the analysis and 6.4% were classified at the discretion of the investigators, underscoring the shortcomings of MSCT. With this major limitation, the per-segment sensitivity and specificity were 81% (95% confidence interval [CI] 72% to 89%) and 93% (95% CI 90% to 97%), respectively, with positive and negative likelihood ratios of 21.5 (95% CI 13.1 to 35.5) and 0.11 (95% CI 0.06 to 0.21), respectively, and positive and negative predictive values of 67.8% (95% CI 57.6% to 78.0%) and 96.5% (95% CI 94.7% to 98.3%), respectively. As expected, the per-patient analysis has shown an increased sensitivity of 96% (95% CI 94% to 98%) but a decreased specificity of 74% (95% CI 65% to 84%). CONCLUSIONS Multislice spiral computed tomography has shortcomings difficult to overcome in daily practice and, at the more clinically relevant per-patient analysis, continues to have moderate specificity in patients with high prevalence of CAD. Studies evaluating the diagnostic performance of the newest generation of MSCT, including patients with low to moderate CAD prevalence, will be critical in establishing the clinical role of this emerging technology as an alternative to CA.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multislice CT Coronary Angiography in Evaluation of Coronary Artery Disease

The investigation and treatment of coronary disease impose a significant burden on health service resources. Catheter coronary angiography remains the gold standard for the investigation of suspected coronary disease. Given the invasive nature and high costs of invasive coronary angiography, there is an increased interest in noninvasive methods to image the lumen of the coronary arteries. Recen...

متن کامل

Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study

Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...

متن کامل

A comparison study between CT angiography with 64-multislice spiral computed tomography and selective X-ray coronary angiography

The aim of this study was to evaluate the diagnostic value of 64-multislice spiral computed tomography (64-MSCT) for coronary stenosis compared with selective X-ray coronary angiography (SCA). Patients with chest pain, chest tightness or coronary stenosis received SCA and they acted as the controls. The sensitivity and accuracy of 64-MSCT were analyzed as compared with SCA. Images from 64-MSCT ...

متن کامل

Multislice computed tomography angiography in the diagnosis of coronary artery disease

Multislice CT angiography represents one of the most exciting technological revolutions in cardiac imaging and it has been increasingly used in the diagnosis of coronary artery disease. Rapid improvements in multislice CT scanners over the last decade have allowed this technique to become a potentially effective alternative to invasive coronary angiography in patients with suspected coronary ar...

متن کامل

CARDIOVASCULAR MEDICINE Assessment of coronary artery stents by 16 slice computed tomography

Objective: To analyse coronary stents with multislice spiral computed tomography (MSCT) in comparison with coronary angiography. Patients and methods: 310 patients referred for conventional coronary angiography underwent MSCT on the next day (16 60.75 mm cross section, 420 ms rotation, 110 ml contrast agent intravenously at 4 ml/ s). Two independent blinded reviewers analysed the MSCT. Results:...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 48 9  شماره 

صفحات  -

تاریخ انتشار 2006