64Cu-DOTATATE PET/MRI for Detection of Activated Macrophages in Carotid Atherosclerotic Plaques
نویسندگان
چکیده
All patients referred to our institution for carotid endarterectomy were screened for inclusion. Inclusion criteria were significant carotid stenosis with recent cerebrovascular symptoms; stroke, amaurosis fugax or TIA. Exclusion criteria were age <50 years, current infection, pregnancy, renal insufficiency, or severe claustrophobia. All patients underwent two simultaneous PET/MR procedures after one injection of a mean of 154 MBq of 64 Cu-DOTATATE. An early PET/MR was performed a median of 85 minutes (range: 56-90 min) after injection and the late PET/MR was performed a median of 299 minutes (range: 265-428 min) after injection. Carotid endarterectomy was performed the following day using standard clinical procedure. The plaque specimens were conserved for later gene expression analysis. The study was approved by the Regional Scientific Ethical Committee (protocol H-4-2012-064) and all patients received oral and written information about the study and signed an informed consent prior to inclusion. In-vivo PET/MR acquisition Simultaneous PET/MR was performed on the Biograph mMR 1 (Siemens Healthcare, Erlangen, Germany) using the mMR standard PET compatible dedicated head and neck coil (Siemens Healthcare). Patients were placed in the scanner in the supine position and scout images were obtained for localization of the carotid arteries. An mMR standard Dixon water-fat MR sequence was then recorded and segmented (into air, lung tissue, soft tissue and fat) for MR-based PET attenuation correction 2. PET acquisition was started along with the Dixon MR sequence. Acquisition time was 10 min in three-dimensional list-mode (scanner default list mode recording) in one bed position. A 3D time-of-flight (TOF) magnetic resonance angiography sequence was then performed to obtain lumen contours. MR parameters for 3D-TOF were: TR/TE 21/3.6 ms, voxel size 0.8×0.5×1.0 mm 3. Next, a stack of 14 axial 2D turbo spin echo dark blood slices (thickness 2.2 mm, gap 0.88 mm, field of view 150 mm) with fat suppression and proton density, T1 and T2 weightings was placed using the 3D-TOF angiography. Images were centered at the stenotic area. MR parameters were: T1-weighted: TR/TE=1,060/26 ms, voxel size 0.6×0.6 mm 2. T2-weighted: TR/TE=2,500/76 ms, voxel size 0.6×0.6 mm 2. Proton density-weighted: TR/TE=2,400/16 ms, voxel size 0.4×0.4 mm 2. For detailed MR parameters of 3D TOF, T1, T2 and proton density-weighted sequences see supplementary material. On average, the total examination time was below 30 minutes. The carorid artery was analyzed slice by slice on transaxial images in every subject guided by T1, T2, TOF and PD images by the …
منابع مشابه
64Cu-DOTATATE PET/MRI for Detection of Activated Macrophages in Carotid Atherosclerotic Plaques: Studies in Patients Undergoing Endarterectomy.
OBJECTIVE A feature of vulnerable atherosclerotic plaques of the carotid artery is high activity and abundance of lesion macrophages. There is consensus that this is of importance for plaque vulnerability, which may lead to clinical events, such as stroke and transient ischemic attack. We used positron emission tomography (PET) and the novel PET ligand [(64)Cu] [1,4,7,10-tetraazacyclododecane-N...
متن کاملMultimodality PET/MR imaging agents targeted to activated macrophages
The recent emergence of multimodality imaging, particularly the combination of PET and MRI, has led to excitement over the prospect of improving detection of disease. Iron oxide nanoparticles (IONPs) have become a popular platform for the fabrication of PET/MRI probes due to their advantages of high MRI detection sensitivity, biocompatibility, and biodegradability. In this paper, we report the ...
متن کاملDetection of Atherosclerotic Inflammation by 68Ga-DOTATATE PET Compared to [18F]FDG PET Imaging
BACKGROUND Inflammation drives atherosclerotic plaque rupture. Although inflammation can be measured using fluorine-18-labeled fluorodeoxyglucose positron emission tomography ([18F]FDG PET), [18F]FDG lacks cell specificity, and coronary imaging is unreliable because of myocardial spillover. OBJECTIVES This study tested the efficacy of gallium-68-labeled DOTATATE (68Ga-DOTATATE), a somatostati...
متن کاملEvaluation of matrix metalloproteinases in atherosclerosis using a novel noninvasive imaging approach.
OBJECTIVE Despite great advances in our knowledge, atherosclerosis continues to kill more people than any other disease in the Western world. This is because our means of identifying truly vulnerable patients is limited. Prediction of atherosclerotic plaque rupture may be addressed by MRI of activated matrix metalloproteinases (MMPs), a family of enzymes that have been implicated in the vulnera...
متن کاملAssessment of vulnerable atherosclerotic and fibrotic plaques in coronary arteries using (68)Ga-DOTATATE PET/CT.
Activated macrophages which express somatostatin receptor-2 (SSTR-2) play a vital role in rupture of the vulnerable atherosclerotic plaques, which result in death. (68)Ga-DOTATATE binds to somatostatin receptors 2, and therefore, can serve as potential radiotracer to detect atherosclerotic plaques. The purpose of this study was to generate preliminary data with this agent in vulnerable or fibro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 35 شماره
صفحات -
تاریخ انتشار 2015