Medical 6 MeV linear accelerator made in Japan.
نویسندگان
چکیده
A 6 MeV medical linear accelerator manufactured by the Mitsubishi Heavy Industries, Ltd., has been installed in the Aichi Cancer Center Hospital. This is the first unit of this type made in Japan. This paper giv'es a brief description of the unit, reports the results of a series 'of tests for radiation and mechanical accuracy, and summarizes the one year history of calibration and stability. One of the most striking characteristic is a mechanism that deflects the electron beam, coming out of the acceleration tube at 180 degrees and using two steps deflection magnet system. The maximum X-ray output was 465 R/min at one meter from the target with the actual maximum energy of 5.75 MeV. The unit was used for clinical radiotherapy for the past year, and treatment was only interrupted one day because of mechanical trouble.
منابع مشابه
Effective Source-Surface Distance in Various Field Sizes and Electron Beam Energies and its Effect on Cutout Factor in a Elekta Precise Linear Accelerator
Introduction: In electron beam treatment, because of the non-point electron beam source, inverse-square law cannot be applied for dosimetry in different treatment intervals. Therefore, providing source-surface distance (SSD) charts in all clinics is of paramount importance. This study aimed to determine the effective SSD for various electron beam energies and field sizes and to...
متن کاملSiemens primus accelerator simulation using EGSnrc Monte Carlo code and gel dosimetry validation with optical computed tomography system by EGSnrc code
Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...
متن کاملMonte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy
Introduction: In recent decades, several Monte Carlo codes have been introduced for research and medical applications. These methods provide both accurate and detailed calculation of particle transport from linear accelerators. The main drawback of Monte Carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...
متن کاملSystematic and comprehensive analysis of the dose-response characteristics of a morning quality check of a linear accelerator and an important application of accelerator performance prediction
Background: This paper aimed to analyze the output constancy of a medical linear accelerator using PTW QUICKCHECKwebline and studied the sensitivity of the PTW QUICKCHECKwebline. Materials and Methods: The paper statistically analyzed the output doses of 6 MV and 10 MV of photons and 6 MeV, 9 MeV, and 12 MeV of electrons from a medical linear accelerator measured before the daily treatment to ...
متن کاملReview of Accelerator-based Boron Neutron Capture Therapy Machines
Accelerator-based BNCT (Boron Neutron Capture Therapy) facilities are being studied, developed and constructed at many laboratories and hospitals, especially in Japan. In order to provide sufficient neutron flux in the epi-thermal energy region (0.5 ~ 10 keV), an intense proton beam accelerated with a cyclotron, linear accelerator (linac) or DC accelerator up to 2.5 ~ 30 MeV is directed to lith...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Nagoya journal of medical science
دوره 32 3 شماره
صفحات -
تاریخ انتشار 1970