Film retakes in digital and conventional radiography.

نویسندگان

  • Waseem Akhtar
  • Mubashir Aslam
  • Arif Ali
  • Kashif Mirza
  • Nadeem Ahmad
چکیده

OBJECTIVE To determine the film-retake rates and causes in digital radiography comparison to conventional X-rays method. STUDY DESIGN Comparative study. PLACE AND DURATION OF STUDY Radiology Department, Aga Khan University Hospital, Karachi, from January 2004 to December 2006. PATIENTS AND METHODS X-rays of different body parts, conducted during the year 2004, with conventional radiography (n=170300), and in 2006 with digital radiography (n=174550), were included in this study. Measurements were done for number of X-rays re-take due to different quality control reasons for both the conventional and digital radiography. Quality control reasons included underexposure, overexposure, positioning errors, patient movements, portable X-rays, grid cutoff, and others (i.e. equipment related) due to which X-ray quality was questionable. Results were expressed in percentages. RESULTS A total of 9423 X-rays (5.5%) were repeated in conventional radiography (n=170300) due to underexposure (38%), overexposure (28.5%), positioning errors (25%), portable procedures (4%), patient movement (2%), grid cut-off (0.5%), and others (2%). Underexposure was the most frequently responsible factor for the X-ray repetition as compared to other factors (p<0.001). In digital radiography (n=174550), 1464 X-rays (1%) needed to be repeated, which was significantly less in comparison to X-ray repetition in conventional method of radiography (5.5%) [p<0.001]. In digital radiography, the most frequent factor for X-ray re-take was positioning error (435, 30%). CONCLUSION Digital radiography is associated with significantly lesser number of re-take X-rays as compared to conventional radiography, hence minimizes the exposure of the patients to unnecessary radiations due to re-take X-rays. Positioning error remains a problem even in digital radiography, emphasizing training need for technologists.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro Comparison of Conventional Film and Direct Digital Radiography in Proximal Caries Detection

Introduction: Various systems for intraoral digital radiography have been available as an alternative to film–based radiography. In consideration of several advantages of digital radiography such as less patient absorbed dose, manipulation of im‌age quality and elimination of processing, it has been extensively used in different fields of denti‌stry in recent years. The purpose of this study wa...

متن کامل

Comparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects

Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects.&nbsp; Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...

متن کامل

Reduction in retake rates and radiation dosage through computed radiography.

The availability of computed radiography has opened the possibility of using reduced dosage for radiographs in clinical settings and reducing the retake rate. A prospective controlled study was carried out over a period of four months comparing conventional X-rays and computed radiography. The aim was to assess if computed radiography at 50% normal dosage would result in films of adequate quali...

متن کامل

Comparison of Accuracy and Observer Agreement in the Detection of Simulated External Root Resorption Using Conventional Digital Radiography and Digitally Filtered Radiography

Introduction: External root resorption is a clinical problem that often cannot be detected clinically. Thus, radiography plays a crucial role in its diagnosis. However, optimal radiographic quality with minimal radiation exposure {2.1 [EN] Verify English word/phrase choice} is an important factor in selecting the appropriate radiographic technique. The aim of this study was the comparison of ac...

متن کامل

بررسی دقت دانسیتومتری اپتیک فیلم های رادیوگرافی و دانسیتومتری در سیستم رادیوویزیوگرافی به صورت In-vitro

Nowadays, bone mass estimation, through imaging methods, is widely used in metabolic diseases diagnosis and treatment. One of these methods is called "optical densitometry" which estimates bone density by measuring the intensity of the transmitted light on different parts of a radiographic image. Digital radiography systems act similarly by determining grey levels of the image. The aim of this ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the College of Physicians and Surgeons--Pakistan : JCPSP

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 2008