Clinical outcomes using ClearPoint interventional MRI for deep brain stimulation lead placement in Parkinson's disease.

نویسندگان

  • Jill L Ostrem
  • Nathan Ziman
  • Nicholas B Galifianakis
  • Philip A Starr
  • Marta San Luciano
  • Maya Katz
  • Caroline A Racine
  • Alastair J Martin
  • Leslie C Markun
  • Paul S Larson
چکیده

OBJECTIVE The ClearPoint real-time interventional MRI-guided methodology for deep brain stimulation (DBS) lead placement may offer advantages to frame-based approaches and allow accurate implantation under general anesthesia. In this study, the authors assessed the safety and efficacy of DBS in Parkinson's disease (PD) using this surgical method. METHODS This was a prospective single-center study of bilateral DBS therapy in patients with advanced PD and motor fluctuations. Symptom severity was evaluated at baseline and 12 months postimplantation using the change in Unified Parkinson's Disease Rating Scale (UPDRS) Part III "off" medication score as the primary outcome variable. RESULTS Twenty-six PD patients (15 men and 11 women) were enrolled from 2010 to 2013. Twenty patients were followed for 12 months (16 with a subthalamic nucleus target and 4 with an internal globus pallidus target). The mean UPDRS Part III "off" medication score improved from 40.75 ± 10.9 to 24.35 ± 8.8 (p = 0.001). "On" medication time without troublesome dyskinesia increased 5.2 ± 2.6 hours per day (p = 0.0002). UPDRS Parts II and IV, total UPDRS score, and dyskinesia rating scale "on" medication scores also significantly improved (p < 0.01). The mean levodopa equivalent daily dose decreased from 1072.5 ± 392 mg to 828.25 ± 492 mg (p = 0.046). No significant cognitive or mood declines were observed. A single brain penetration was used for placement of all leads, and the mean targeting error was 0.6 ± 0.3 mm. There were 3 serious adverse events (1 DBS hardware-related infection, 1 lead fracture, and 1 unrelated death). CONCLUSIONS DBS leads placed using the ClearPoint interventional real-time MRI-guided method resulted in highly accurate lead placement and outcomes comparable to those seen with frame-based approaches.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomical situation of the subthalamic nucleus (STN) from midcommissural point (MCP) in Parkinson\'s disease patients underwent deep brain stimulation (DBS): an MRI targeting study

  Abstract   Introduction: It is demonstrated that the degree of clinical improvement in   Parkinson's disease (PD) achieved by deep brain stimulation (DBS) is largely dependent   on the accuracy of lead placement. In addition, individual variability in the   situation of subthalamic nucleus (STN) is responsible for spatial inter-individual   fluctuations of the real patient's target.   Objecti...

متن کامل

Rapid subthalamic nucleus deep brain stimulation lead placement utilising CT/MRI fusion, microelectrode recording and test stimulation.

Subthalamic nucleus (STN) deep brain stimulation (DBS) has become an established treatment strategy for patients with medically refractory Parkinson's disease (PD). There are however numerous strategies employed for STN lead placement. Variations include method of STN localisation, use of microelectrode recording, number of microelectrode recording passes and time taken for the procedure. We de...

متن کامل

Closed- and Open-loop Deep Brain Stimulation: Methods, Challenges, Current and Future Aspects

Deep brain stimulation (DBS) is known as the most effective technique in the treatment of neurodegenerative diseases, especially Parkinson disease (PD) and epilepsy. Relative healing and effective control of disease symptoms are the most significant reasons for the tangible tendency in use and development of this technology. Nevertheless, more cellular and molecular investigations are required ...

متن کامل

Coordinate-Based Lead Location Does Not Predict Parkinson's Disease Deep Brain Stimulation Outcome

BACKGROUND Effective target regions for deep brain stimulation (DBS) in Parkinson's disease (PD) have been well characterized. We sought to study whether the measured Cartesian coordinates of an implanted DBS lead are predictive of motor outcome(s). We tested the hypothesis that the position and trajectory of the DBS lead relative to the mid-commissural point (MCP) are significant predictors of...

متن کامل

MRI-guided STN DBS in Parkinson's disease without microelectrode recording: efficacy and safety.

Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a commonly employed therapeutic procedure for patients with Parkinson's disease uncontrolled by medical therapies. This series describes the outcomes of 79 consecutive patients that underwent bilateral STN DBS at the National Hospital for Neurology and Neurosurgery between November 2002 and November 2008 using an MRI-guided surgic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of neurosurgery

دوره 124 4  شماره 

صفحات  -

تاریخ انتشار 2016