Electron spectroscopy using two-dimensional electron detection and a camera in a single electron counting mode.
نویسندگان
چکیده
A brief description is given of an economical implementation of the read out of a two-dimensional detector in an electron spectrometer by a charge coupled device camera, using a pulse counting mode. Count rates up to 10 kHz can be handled in this way. A comparison with results obtained using a resistive anode detector is given for the case of electron scattering from Xe atoms. Good agreement was obtained between both detection techniques, establishing the validity of the method described here.
منابع مشابه
Performance of a direct detection camera for off-axis electron holography.
The performance of a direct detection camera (DDC) is evaluated in the context of off-axis electron holographic experiments in a transmission electron microscope. Its performance is also compared directly with that of a conventional charge-coupled device (CCD) camera. The DDC evaluated here can be operated either by the detection of individual electron events (counting mode) or by the effective...
متن کاملInvestigation of the operation of Thick Gas Electron Multiplier and Electron Multiplier Assembly for alpha particle detection
In this study, the detection of alpha particles in the high current mode is investigated in the presence of two gaseous electron multipliers in the micro-pattern structures. Thick Gas Electron Multiplier (TGEM) and an Electron Multiplier Assemblies (EMA) were designed and constructed as amplification gap in the detector chamber. An ion chamber is employed to measure the current of interaction b...
متن کاملConduction coefficient modeling in bilayer graphene based on schottky transistors
Nowadays carbon nanoparticles are applied on the island of single electron transistor and Nano-transistors. The basis of single electron devices (SEDs) is controllable single electron transfer between small conducting islands. Based on the important points in quantum mechanics, when a wave passes through several spatial regions with different boundaries, the wave function of the first region di...
متن کاملRoom Temperature Hydrogen Sensor Based on Single-Electron Tunneling Between Palladium Nanoparticles
In this paper, we present the results of single-electron tunneling in two-dimensional (2D) hexagonal closed packed arrays of palladium nanoparticles. After inspecting the emergence of Coulomb blockade phenomena, we demonstrate the possibilities of using these arrays as a single-electron tunneling based hydrogen sensor. We assumed arrays of palladium nanoparticles with diameters of 3.5 and 6...
متن کاملEvaluation of super-resolution performance of the K2 electron-counting camera using 2D crystals of aquaporin-0.
The K2 Summit camera was initially the only commercially available direct electron detection camera that was optimized for high-speed counting of primary electrons and was also the only one that implemented centroiding so that the resolution of the camera can be extended beyond the Nyquist limit set by the physical pixel size. In this study, we used well-characterized two-dimensional crystals o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 80 6 شماره
صفحات -
تاریخ انتشار 2009