Supraspinatus tendon repair using anchors: a biomechanical evaluation in the rabbit
نویسندگان
چکیده
BACKGROUND Arthroscopic rotator cuff repairs are mostly secured with suture anchors and often supplemented by footprint decortication. The objectives of this study were to characterize the strength of bone-tendon healing following anchor repair and assess the effect of channeling the supraspinatus (SSP) humeral footprint 1 week ahead of reattachment surgery. METHODS One hundred twelve rabbits underwent unilateral detachment of one SSP tendon and were randomly assigned to two groups: channeling the footprint at time of detachment and no channeling. One week later, reattachment was performed using an anchor. The repaired and contralateral shoulders were harvested at 0, 1, 2, or 4 weeks after repair and mechanically tested to failure. Outcome measures included load at failure, stiffness, and site of failure. RESULTS Anchor fixation had a mean load at failure of 81 ± 32 N and a stiffness of 27 ± 9 N/mm immediately after repair compared to 166 ± 47 N and 66 ± 13 N/mm in the contralateral (both p < 0.05). Mechanical recovery of the reattached SSP tendon was achieved after 4 weeks (221 ± 73 N, 206 ± 59 N, and 198 ± 49 N in the channeling, no channeling, and contralateral groups, respectively, p > 0.05). The dominant site of failure shifted from the footprint at 0/1 week to bone avulsion/mid-substance tear at 4 weeks (p < 0.05). There were no differences in outcomes between the channeling and no channeling groups. CONCLUSIONS This study is the first of its kind to provide quantitative data on the mechanical properties of the enthesis following anchor repair in a rabbit model. Anchor repair led to rapid and complete restoration of SSP mechanical properties. Further evidence is needed before recommending channeling ahead of repair surgery.
منابع مشابه
Biomechanical comparison of traditional anchors to all-suture anchors in a double-row rotator cuff repair cadaver model.
BACKGROUND To further reduce the invasiveness of arthroscopic rotator cuff repair surgery the all-suture anchor has been developed. The all-suture anchor requires less bone removal and reduces the potential of loose body complications. The all-suture anchor must also have adequate biomechanical strength for the repair to heal. The hypothesis is there is no significant difference in the biomecha...
متن کاملBiomechanical evaluation of transosseous rotator cuff repair: do anchors really matter?
BACKGROUND Suture anchor fixation has become the preferred method for arthroscopic repairs of rotator cuff tears. Recently, newer arthroscopic repair techniques including transosseous-equivalent repairs with anchors or arthroscopic transosseous suture passage have been developed. PURPOSE To compare the initial biomechanical performance including ultimate load to failure and localized cyclic e...
متن کاملBiomechanical performance of rotator cuff repairs with humeral rotation: a new rotator cuff repair failure model.
BACKGROUND Traditional biomechanical evaluations of rotator cuff repair techniques employ cyclic loading of the supraspinatus tendon in an isolated medial direction. PURPOSE This study was conducted to evaluate 2 different rotator cuff repair techniques that are currently the subject of debate with cyclic loading and with internal and external humeral rotation to better simulate postoperative...
متن کاملEvaluation of tendon healing using fibroblast like synoviocytes in rabbits: A biomechanical study
Tendon never restores the complete biological and mechanical properties after healing. Several techniques are available for tissue-engineered biological augmentation for tendon healing like stem cells. Recently, synovium has been investigated as a source of cells for tissue engineering. In the present study, we investigated potentials of fibroblast like synoviocytes (FLSs) in tendon healing. Si...
متن کاملKnotless single-row rotator cuff repair: a comparative biomechanical study of 2 knotless suture anchors.
The purpose of this study was to compare the gap formation during cyclic loading, maximum repair strength, and failure mode of single-row full-thickness supraspinatus repairs performed using 2 knotless suture anchors with differing internal suture-retention mechanisms in a human cadaver model. Nine matched pairs of cadaver shoulders were used. Full-thickness tears were induced by detaching the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 13 شماره
صفحات -
تاریخ انتشار 2018