The distance between the vein and lesions predicts the requirement of carina ablation in circumferential pulmonary vein isolation.

نویسندگان

  • Yenn-Jiang Lin
  • Hsuan-Ming Tsao
  • Shih-Lin Chang
  • Li-Wei Lo
  • Ta-Chuan Tuan
  • Yu-Feng Hu
  • Wen-Chin Tsai
  • Chien-Jung Chang
  • Ching-Tai Tai
  • Kazuyoshi Suenari
  • Shih-Yu Huang
  • Tsu-Juey Wu
  • Shih-Ann Chen
چکیده

AIMS Additional ablation in the pulmonary vein (PV) carina region is sometimes required to achieve electrical isolation following circumferential pulmonary vein isolation (PVI). This study investigated the procedural predictors for the requirement of additional carina ablation to achieve complete electrical isolation with PVI. METHODS AND RESULTS Eighty patients with drug-refractory paroxysmal AF underwent circumferential PVI. After the first round of PVI, we placed circular catheters inside the veins to identify the residual PV potentials, and also performed electroanatomic mapping to observe the earliest activation sites during sinus rhythm. The requirement of an additional gap and carina ablation, and the optimal distance that predicted an incomplete PV block were assessed. In the first 40 patients, 43% of the ipsilateral PVs were electrically isolated after the initial PVI. Subsequent ablation of the gaps and ablation of the carina were required in the remaining 57% PVs. The only predictor of the requirement of carina ablation was the mean distance between the lesion-related scar and the ostia (P = 0.03). The longer the distance from the isolating lesions to the PV ostia (>8 mm) predicted an incomplete PV isolation after the first round of circumferential isolation. In the next 40 patients, a fixed distance of 8 mm to the PV ostia decreased the requirement of a carina ablation and resulted in a shorter procedure time (P < 0.05). CONCLUSIONS This study indicated the importance of complete linear lesions and additional carina ablation when the wide area circumferential PV isolation was applied.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary vein isolation by circumferential radiofrequency lesions in atrial fibrillation. From substrate to clinical outcome.

Circumferential ablation around pulmonary vein ostia by CARTO system was performed in 98 patients with paroxysmal and 29 with permanent atrial fibrillation (AF). Preablation and postablation activation, propagation and voltage maps were obtained. A total of 135 +/- 18 radiofrequency pulses were delivered. After a follow-up of 14.7 +/- 3.3 months, 84 patients with paroxysmal and 22 with chronic ...

متن کامل

Freedom from atrial tachyarrhythmias after catheter ablation of atrial fibrillation: a randomized comparison between 2 current ablation strategies.

BACKGROUND Data on the comparative value of the circumferential pulmonary vein and the segmental pulmonary vein ablation for interventional treatment of atrial fibrillation are limited. We hypothesized that the circumferential pulmonary vein ablation approach was superior to the segmental pulmonary vein ablation approach. METHODS AND RESULTS One hundred patients with highly symptomatic atrial...

متن کامل

Simultaneous isolation of the four pulmonary veins by single-sided antral ablation

Figure 1 Intracardiac tracings from the left superior pulmonary vein (LSPV), left inferior pulmonary vein (LIPV), right superior pulmonary vein (RSPV), right inferior pulmonary vein (RIPV) and coronary sinus (CS): before ablation (left) and after left antral circumferential ablation (center). Transthoracic echocardiogram showing severe right atrial and right ventricular dilatation with apical d...

متن کامل

Three-dimensional impedance mapping as an aid to circumferential pulmonary vein isolation in paroxysmal atrial fibrillation.

During circumferential pulmonary vein isolation, radiofrequency lesions are created in the transition zone between the left atrium and the pulmonary veins, outside the ostia, to avoid stenosis. Three-dimensional impedance maps were constructed for 25 patients with paroxysmal atrial fibrillation. In the first 15 patients, impedance was measured inside the pulmonary veins (165.4 +/- 7.5 Omega), t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 13 3  شماره 

صفحات  -

تاریخ انتشار 2011