[Influence of daily set-up errors on dose distribution during pelvis radiotherapy].

نویسندگان

  • Mladen Kasabašić
  • Vedran Rajevac
  • Slaven Jurković
  • Ana Ivković
  • Hrvoje Sobat
  • Dario Faj
چکیده

An external beam radiotherapy (EBRT) using megavoltage beam of linear accelerator is usually the treatment of choice in cancer patients. The goal of EBRT is to deliver the prescribed dose to the target volume, with as low as possible dose to the surrounding healthy tissue. A large number of procedures and different professions involved in radiotherapy, uncertainty of equipment and daily patient set-up errors can cause a difference between the planned and delivered dose.We investigated a part of this difference caused by measuring daily patient set-up errors for 35 patients. These set-up errors were simulated on five patients, using 3D treatment planning software XiO. The simulation investigated differences in dose distributions between the planned and shifted geometry. Additionally, we investigated the influence of the error on treatment plan selection by analysing changes in dose volume histograms, planning target volume conformity index (CIPTV), and homogeneity index (HI).Simulations showed that patient daily set-up errors can cause significant differences between the planned and actual dose distributions. Moreover, for some patients, those errors could affect the choice of treatment plan since CIPTV fell under 97%. Surprisingly, HI was not as sensitive to set-up errors as CIPTV. Our results have confirmed the need to minimise daily set-up errors through quality assurance programmes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Effect Resulting From the Collimator Angle, the Isocenter Move, and the Gantry Angle Errors

Introduction: Dose distribution can be affected by diverse parameters, such as beam orientations, and collimator angles. These parameters should respect and maintain the international recommended levels during the realization of the quality assurance protocols of linear accelerators. This study aimed at evaluating the dosimetric effects on treatment quality considering...

متن کامل

بررسی صحیح بودن مقدار اشعه داده شده در پرتودرمانی سرطان پستان با ترمولومینسانس دوزیمتری

In vivo dosimetry seems an appropriate method for quality assurance in radiotherapy with CO-60, which can be considered as a routine program in radiotherapy centers. In this study, entrance and exit dose in tangential fields were measured in phantom for 30 breast cancer patients by using TLD in radiotherapy section of Imam Khomeini Hospital. TLD crystals were calibrated against SSDL (Secondary...

متن کامل

EPID in vivo Dosimetry

Introduction: The most modern radiotherapy devices are equipped with an Electronic Portal Imaging Device (EPID) system which is located on opposite side of the machine’s head. EPID system is often used to setting up the position verification during or between radiotherapy sessions. Material and Methods: Various types of dosimeters have been used to setting up ...

متن کامل

Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins

PURPOSE The purpose of the study was to evaluate the patient set-up error of different anatomical sites, to estimate the effect of different frequencies of online verifications on the patient set-up accuracy, and to calculate margins to accommodate for the patient set-up error (ICRU set-up margin, SM). METHODS AND MATERIALS Alignment data of 148 patients treated with inversed planned intensit...

متن کامل

Accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID)

Background: To correct patient positioning errors (setup errors) during prostate cancer treatment using EPID and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. Materials and Methods: Fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field IMRT planning technique. The p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arhiv za higijenu rada i toksikologiju

دوره 62 3  شماره 

صفحات  -

تاریخ انتشار 2011