A new test of Time Dilation at ESR using fast 7Li+-ions

نویسندگان

  • B. Botermann
  • T. Kühl
  • W. Nörtershäuser
  • C. Novotny
  • R. Sánchez
  • T. Stöhlker
  • C. Geppert
  • G. Huber
  • S. Karpuk
  • D. Bing
  • D. Schwalm
  • A. Wolf
  • G. Gwinner
  • T. W. Hänsch
  • S. Reinhardt
  • G. Saathoff
چکیده

B. Botermann1,2, T. Kühl1, W. Nörtershäuser1,2, C. Novotny1,2, R. Sánchez1, T. Stöhlker1, C. Geppert2, G. Huber2, S. Karpuk2, D. Bing3, D. Schwalm3, A. Wolf3, G. Gwinner4, T. W. Hänsch5, S. Reinhardt5, and G. Saathoff5 1GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany; 2Johannes Gutenberg Universität Mainz, Germany; 3MPI für Kernphysik, Heidelberg, Germany; 4University of Manitoba, Winnipeg, Canada; 5MPI für Quantenoptik, Garching, Germany

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Test of time dilation using stored Li+ ions as clocks at relativistic speed.

We present the concluding result from an Ives-Stilwell-type time dilation experiment using 7Li+ ions confined at a velocity of β=v/c=0.338 in the storage ring ESR at Darmstadt. A Λ-type three-level system within the hyperfine structure of the 7Li+3S1 →3P2 line is driven by two laser beams aligned parallel and antiparallel relative to the ion beam. The lasers' Doppler shifted frequencies require...

متن کامل

Experimental test of special relativity by laser spectroscopy

The Doppler-free laser-spectroscopic frequency measurement of Doppler-shifted optical lines in forward and backward direction of a fast ion beam permits a sensitive test of the relativistic Doppler-formula and, hence, the relativistic time dilation factor γSR 1⁄4 ð1 ν2 c2 1=2. An experiment on metastable Li, stored at a velocity of v= 0.064c in the Heidelberg heavy-ion storage ring TSR, has con...

متن کامل

Application of FFT Cyclic Voltammetry for Monitoring Removal of Mercury Ions from Aqueous Environment using New Adsorbent based Modified Mesoporous Silica (SBA–15)

As the electrochemical method, the Fast Fourier Transform (FFT) Stripping Cyclic Voltammetry detection method was designed for measurement and monitoring of adsorbed mercury ions by new modified adsorbent based on mesoporous silica as a new adsorbent. In this respect, SBA-15 as mesoporous silica and 1, 3, 5 Trithiane as effective modifier ligand were chosen, and the modification process was car...

متن کامل

Test of relativistic time dilation with fast optical atomic clocks at different velocities

Time dilation is one of themost fascinating aspects of special relativity as it abolishes the notion of absolute time. It was first observed experimentally by Ives and Stilwell in 1938 using the Doppler effect. Here we report on a method, based on fast optical atomic clocks with large, but different Lorentz boosts, that tests relativistic time dilation with unprecedented precision. The approach...

متن کامل

Measurement of Time Dilation by Laser Spectroscopy on Fast Stored Lithium Ions

In this work frequency measurements on fast lithium ions as a test of time dilation are presented. The measurements are carried out at the Max Planck Institute for Nuclear Physics in Heidelberg using the storage ring TSR. The transition frequency of a two-level system in the lithium ion is measured using a Doppler-free fluorescence saturation spectroscopy. The spectroscopy is realized by two co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010