Performance of the Abbott RealTime CT/NG for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

نویسندگان

  • C A Gaydos
  • C P Cartwright
  • P Colaninno
  • J Welsch
  • J Holden
  • S Y Ho
  • E M Webb
  • C Anderson
  • R Bertuzis
  • L Zhang
  • T Miller
  • G Leckie
  • K Abravaya
  • J Robinson
چکیده

A multicenter clinical study was conducted to evaluate the performance characteristics of the Abbott RealTime CT/NG assay, a multiplex real-time PCR assay, for simultaneous detection of Chlamydia trachomatis and Neisseria gonorrhoeae. The specimens were collected from a total of 3,832 male and female subjects at 16 geographically diverse sites. Specimens included male and female urine samples, male urethral swabs, female endocervical swabs, and self-collected and clinician-collected vaginal swabs. Specimens were tested with the automated Abbott RealTime CT/NG assay, Aptima Combo 2 assay (Gen-Probe), ProbeTec ET CT/GC assay (Becton Dickinson), and culture for N. gonorrhoeae. The Aptima Combo 2 assay, the ProbeTec assay, and the N. gonorrhoeae culture were used as the reference assays. For each subject, a patient infected status (PIS) was determined based on the combined results from the reference assays. The overall prevalence in female subjects was 8.9% for C. trachomatis and 3.8% for N. gonorrhoeae. The overall male prevalence was 18.2% for C. trachomatis and 16.7% for N. gonorrhoeae. The overall sensitivity and specificity of the Abbott RealTime CT/NG assay were 92.4% and 99.2% for C. trachomatis and 96.9% and 99.7% for N. gonorrhoeae, respectively. In comparison, the sensitivity and specificity, respectively, for the Aptima Combo 2 assay were 94.5% and 99.0% for C. trachomatis and 96.1% and 99.5% for N. gonorrhoeae, and those for the ProbeTec ET assay were 90.3% and 99.5% for C. trachomatis and 92.0% and 97.3% for N. gonorrhoeae in this study. The Abbott RealTime CT/NG assay offers C. trachomatis and N. gonorrhoeae dual detection with high sensitivity and specificity. The automated assay provides a useful alternative nucleic acid amplification assay for clinical laboratories and clinicians.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Abbott RealTime CT/NG Assay for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Cervical Swabs from Female Sex Workers in China

BACKGROUND To evaluate the performance of the Abbott RealTime CT/NG assay for detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) among female sex workers (FSWs) in China. METHODS Cervical swabs from 997 participants were blindly detected by the Abbott RealTime CT/NG assay on the automated m2000 molecular platform and Roche Cobas Amplicor CT/NG assay. Discrepant analysis we...

متن کامل

Evaluation of three automated nucleic acid amplification systems for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in first-void urine specimens.

A total of 500 first-void urine specimens were tested for the presence of Chlamydia trachomatis and Neisseria gonorrhoeae nucleic acids using ProbeTec ET reagents on a Viper platform (BD Diagnostics, Mississauga, Ontario, Canada), Aptima Combo 2 reagents on a Tigris platform (Gen-Probe, Inc., San Diego, CA), and Abbott RealTime CT/NG reagents on an m2000 platform (Abbott Molecular Diagnostics, ...

متن کامل

Performance of the Abbott Real Time CT/NG assay in urines and cervico-vaginal samples from Senegal.

INTRODUCTION Chlamydia trachomatis and Neisseria gonorrhoeae are the most common causes of sexually transmitted disease in Senegal and worldwide. Molecular techniques have become the standard for their detection, and due to the frequency of co-infections, these tests can detect both agents and can be used on urine samples, vaginal swabs, or endocervical samples. In developing countries, the use...

متن کامل

Performance evaluation of the PelvoCheck CT/NG test kit for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae

OBJECTIVE Assessment of the performance of the PelvoCheck CT/NG test (Greiner-Bio-One GmbH) to detect Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) in first-void urine (FVU) of females. DESIGN A cross-sectional study to compare the PelvoCheck CT/NG with COBAS TaqMan CT Test V.2.0 (Roche) for the detection of CT and with an in-house porA-based PCR for the detection of NG in FVU spe...

متن کامل

Performance of cobas® 4800 and m2000 real-time™ assays for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in rectal and self-collected vaginal specimen.

A prospective, multicenter trial was designed to compare the performance characteristics of the cobas® 4800 (Roche Diagnostics, Indianapolis, IN, USA) and m2000 real-time™ (Abbott Molecular Inc., Des Plaines, IL, USA) assays for detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) in rectal and self-collected vaginal swabs. Rectal (n = 234) or self-collected vaginal swabs (n =...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 48 9  شماره 

صفحات  -

تاریخ انتشار 2010