Liquid-chromatographic determination of eight tri- and tetracyclic antidepressants and their major active metabolites.

نویسندگان

  • T A Sutfin
  • R D'Ambrosio
  • W J Jusko
چکیده

A "high-performance" liquid-chromatographic method is presented for monitoring the therapeutic concentrations, in plasma, of eight tri- and tetracyclic antidepressants (amitriptyline, nortriptyline, imipramine, desipramine, doxepin, clomipramine, maprotiline, and protriptyline) and their major active metabolites. One of two internal standards is added to 0.5 mL of drug-containing plasma, the pH is adjusted to about 9.5 with borate buffer, and the sample is extracted with isoamyl alcohol in hexane. The extracts are chromatographed on a column of silica and absorbance of the effluent is measured at either 214 or 254 nm. Chromatographic response is linearly related to concentration for all components over a 5-500 ng range. Analytical recovery of the drugs and metabolites from plasma is approximately 75 to 85% at low and high concentrations. Within-run and day-to-day precision (CV) is less than 5% for both high and low concentrations of most of these drugs and metabolites. Parallel analysis of clinical samples by gas chromatography indicates that results by the two techniques are comparable. We report some results of therapeutic monitoring of clinical samples.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma

An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...

متن کامل

Comparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma

An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...

متن کامل

Automated determination of drugs in serum by column-switching high-performance liquid chromatography. IV. Separation of tricyclic and tetracyclic antidepressants and their metabolites.

We describe automated column-switching high-performance liquid chromatography for determining nine tricyclic and tetracyclic antidepressants (TCAs) and their metabolites in human serum. TSKgel ODS-80TM and TSKprecolumn PW (Tosoh Co., Tokyo) are used in the analytical column and the precolumn, respectively. A 200-microL serum sample is directly injected onto the precolumn. After washing the seru...

متن کامل

High Performance Liquid Chromatographic Determination of Inactive Carboxylic Acid Metabolite of Clopidogrel in Human Serum: Application to a Bioequivalence Study

        A sensitive and rapid method is described for determination of clopidogrel carboxylic acid (CCA), the inactive metabolite of the antiplatelet agent clopidogrel in human serum. The analytical procedure involves liquid-liquid extraction of the analyte and an internal standard (phenytoin) with ethyl acetate. A mobile phase consisting of 0.05 M phosphate buffer containing triethylamine (0.5...

متن کامل

High-performance liquid chromatographic determination of ibuprofen and its major metabolites in biological fluids.

A sensitive and selective high-performance liquid-chromatographic assay for ibuprofen and its major metabolites in biological fluids is described. To ensure good chromatographic separation the drug and metabolites were run on a gradient elution system and detected with a variable wavelength detector set at 220 nm. A second, more rapid, isocratic system is also described for the detection of onl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 30 3  شماره 

صفحات  -

تاریخ انتشار 1984