Automated electrical impedance technique for rapid enumeration of fecal coliforms in effluents from sewage treatment plants.

نویسندگان

  • M P Silverman
  • E F Munoz
چکیده

Fecal coliforms growing in a selective lactose-based broth medium at 44.5 degrees C generate a change in the electrical impedance of the culture relative to a sterile control when populations reach 10(6) to 10(7) per ml. The ratio of these changes was measured automatically, and the data were processed by computer. A linear relation was found between the log10 of the number of fecal coliforms in an inoculum and the time required for an electrical impedance ratio signal to be detected. Pure culture inocula consisting of 100 fecal coliforms in log phase or stationary phase were detected in 6.5 and 7.7 h, respectively. Standard curves of log10 fecal coliforms in wastewater inocula versus detection time, based on samples collected at a sewage treatment plant over a 4-month period, were found to vary from one another with time. Nevertheless, detection times were rapid and ranged from 5.8 to 7.9 h for 200 fecal coliforms to 8.7 to 11.4 h for 1 fecal coliform. Variations in detection times for a given number of fecal coliforms were also found among sewage treatment plants. A strategy is proposed which takes these variations into account and allows for rapid, automated enumeration of fecal coliforms in wastewater by the electrical impedance ratio technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid, single-step most-probable-number method for enumerating fecal coliforms in effluents from sewage treatment plants.

A single-step most-probable-number method for enumerating fecal coliforms in sewage treatment plant effluents is described. The method requires the use of only one lactose-based medium and a single incubation temperature of 44.5 degrees C, and it can be completed in 18 h or less, as compared with up to 72 h for the standard most-probable-number method. The appearance of growth is the sole crite...

متن کامل

Membrane filter method for recovery of fecal coliforms in chlorinated sewage effluents.

The standard one-step M-FC broth-membrane-filter procedure for recovery of fecal coliforms from chlorinated sewage effluents is much less effective than the multiple-tube (most-probable-number) technique. A two-step membrane-filter method, using a pre-enrichment technique with phenol red lactose broth and incubation at 35 degrees C for 4 h, followether 18+/-2 h, enhanced fecal coliform recovery...

متن کامل

Evaluation of Methods for Detecting Coliforms and Fecal Streptococci in Chlorinated Sewage Effluents

Total coliform (TC), fecal coliform (FC), and fecal streptococcus (FS) recoveries in chlorinated secondary sewage effluents were investigated by the membrane filter (MF) and multiple-tube (most probable number, MPN) methods. The LES two-step MF method was found to be comparable to the MPN procedure for determining TC. The TC detection was 1.5 times greater by the LES two-step technique than tha...

متن کامل

Fecal Coliform Organism Enumeration in Chlorinated Wastewaters

The accepted method for determining disinfection efficiency of wastewater treatment systems is routinely to perform fecal coliform bacteria analyses on the final effluent (5). Standard Methods for the Examination of Water and Wastewater outlines two procedures for fecal coliform analysis: the membrane filtration technique and the most-probable-number (MPN) method (1). For chlorinated effluents,...

متن کامل

Microbiological indicators of water quality in the Xochimilco canals, Mexico City.

OBJECTIVE To quantify microbiology indicators of fecal contamination in the effluents of two waste water treatment plants and in samples collected in several canals in Xochimilco. MATERIAL AND METHODS A cross sectional study was performed. Ten sites, 5 from plant effluents and 5 from canals, were selected for sampling during November and December 2001. Fecal coliforms and enterococci were qua...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 1979