Long-range Fourier domain optical coherence tomography of the pediatric subglottis.
نویسندگان
چکیده
BACKGROUND Acquired subglottic stenosis (SGS) most commonly results from prolonged endotracheal intubation and is a diagnostic challenge in the intubated child. At present, no imaging modality allows for in vivo characterization of subglottic microanatomy to identify early signs of acquired SGS while the child remains intubated. Fourier domain optical coherence tomography (FD-OCT) is a minimally invasive, light-based imaging modality which provides high resolution, three dimensional (3D) cross-sectional images of biological tissue. We used long-range FD-OCT to image the subglottis in intubated pediatric patients undergoing minor head and neck surgical procedures in the operating room. METHODS A long-range FD-OCT system and rotary optical probes (1.2mm and 0.7mm outer diameters) were constructed. Forty-six pediatric patients (ages 2-16 years) undergoing minor upper airway surgery (e.g., tonsillectomy and adenoidectomy) were selected for intraoperative, trans-endotracheal tube FD-OCT of the subglottis. Images were analyzed for anatomical landmarks and subepithelial histology. Volumetric image sets were rendered into virtual 3D airway models in Mimics software. RESULTS FD-OCT was performed on 46 patients (ages 2-16 years) with no complications. Gross airway contour was visible on all 46 data sets. Twenty (43%) high-quality data sets clearly demonstrated airway anatomy (e.g., tracheal rings, cricoid and vocal folds) and layered microanatomy of the mucosa (e.g., epithelium, basement membrane and lamina propria). The remaining 26 data sets were discarded due to artifact, high signal-to-noise ratio or missing data. 3D airway models were allowed for user-controlled manipulation and multiplanar airway slicing (e.g., sagittal, coronal) for visualization of OCT data at multiple anatomic levels simultaneously. CONCLUSIONS Long-range FD-OCT produces high-resolution, 3D volumetric images of the pediatric subglottis. This technology offers a safe and practical means for in vivo evaluation of lower airway microanatomy in intubated pediatric patients. Ultimately, FD-OCT may be applied to serial monitoring of the neonatal subglottis in long-term intubated infants at risk for acquired SGS.
منابع مشابه
Quantitative Evaluation of Adult Subglottic Stenosis Using Intraoperative Long-range Optical Coherence Tomography.
OBJECTIVES To determine the feasibility of long-range optical coherence tomography (LR-OCT) as a tool to intraoperatively image and measure the subglottis and trachea during suspension microlaryngoscopy before and after endoscopic treatment of subglottic stenosis (SGS). METHODS Long-range optical coherence tomography of the adult subglottis and trachea was performed during suspension microlar...
متن کاملاندازهگیری همزمان ضریب شکست و ضخامت فیزیکی دستگاههای چندلایهای با استفاده از نتایج مقطعنگاری همدوسی اپتیکی در فضای فوریه
In fourier domain optical coherence tomography, we can measure the optical thickness ( refractive index n times thickness d), to obtain the retinal layers in order to diagnose many disorders. In this work, we introduce a new method for measurement of refractive index and physical thickness of multiple layers simultaneously by Fourier domain optical coherence tomography, without additional infor...
متن کاملHigh resolution Fourier domain optical coherence tomography in the 2 μm wavelength range using a broadband supercontinuum source.
A 220 nm bandwidth supercontinuum source in the two-micron wavelength range has been developed for use in a Fourier domain optical coherence tomography (FDOCT) system. This long wavelength source serves to enhance probing depth in highly scattering material with low water content. We present results confirming improved penetration depth in high opacity paint samples while achieving the high axi...
متن کاملبررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک
Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...
متن کاملRetinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography
Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- International journal of pediatric otorhinolaryngology
دوره 79 2 شماره
صفحات -
تاریخ انتشار 2015