Research by the National Institute for Occupational Safety and Health (NIOSH) has pursued quartz analysis for the specialized filter assemblies of a new worker-wearable personal dust monitor (PDM). The PDM is a real-time instrument utilizing a tapered element oscillating microbalance (TEOM). Standard fiberglass TEOM filters cannot accommodate the desired P-7 infrared analytical method used by the Mine Safety and Health Administration (MSHA). Novel filter materials were tested with the objective of demonstrating this type of analysis. Low temperature ashing and spectrometric examination were employed, revealing that nylon fiber candidate filters left minimal residual ash and produced no significant spectral interference. Avoiding titanium dioxide in all filter materials proved to be a key requirement. Fine quartz particulates were collected on prototype filters in a Marple chamber, either open-faced or through PDMs during test runs. The filters were then subjected to MSHA P-7 analysis and the spectrometrically based analytical results for quartz mass were compared to reference measurements. Also, PDM instrumental mass readings were compared to filter gravimetric measurements. Results suggest that the P-7 method is adaptable to variations in filter materials and that quartz dust analysis by the P-7 method when utilizing the new ashable PDM filters can have accuracy and precision within 10% and 4%, respectively. This is within the declared 13% accuracy and 7-10% precision of the P-7 method itself. Instrument mass readings had modest positive bias but met NIOSH accuracy criteria. Continued work with specialized PDM filters is merited, as they are a new type of TEOM sample amenable to ashing analysis of particulates.
منابع مشابه
Monitoring and Method development of Hg in Istanbul Airborne Particulates by Solid Sampling Continuum Source-High Resolution Electrothermal Atomic Absorption Spectromerty
In this work, a method has been developed and monitoring for the determination of mercury in PM2.5 airborne particulates by solid sampling high-resolution continuum source electrothermal atomic absorption spectrometry. The PM2.5 airborne particulates were collected on quartz filters using high volume samplers (500 L/min) in Istanbul (Turkey) for 96 hours every month in one year. At first, exper...
متن کامل[Influence of spectral interferences on the results of quartz determination by infrared spectrometry].
BACKGROUND Determination of quartz by Fourier transform infrared spectrometry (FTIR) is not specific: the obtained results are influenced by matrix components, some of which cause spectral interference. The aim of the study was to evaluate the effect of dust components responsible for spectral interference with quartz on the results of its determinations, and to develop methods to minimize the ...
متن کاملEvaluation of the SKC® DPM cassette for monitoring diesel particulate matter in coal minest
In a previous study, the efficacy of commercial and prototype impactors for sampling diesel particulate matter (DPM) in coal mines was investigated. Laboratory and field samples were collected on quartz-fiber filters and analyzed for organic and elemental carbon. Coal dust contributed a minimal amount of elemental carbon when commercial cascade impactors and prototype impactors, designed by the...
متن کاملEquivalent diameter of standard quartz dust used as a test aerosol for the dust respirator.
In the standard of the approval test for dust respirator certification, test aerosols are defined as air containing quartz particles of 2 microns or smaller1. However, it is well-known that the filtration efficiency of air filters depends on the size of the test aerosol particles. Alternative test aerosols containing submicron size particles will be studied for use in future approval test of du...
متن کاملEvaluation of mechanical prototype machines for continuous separation of respirable cotton dust fractions.
The original cotton particulates analyzer used stationary screens to separate aerodynamically the coarse and fine dust fractions from small samples of cotton. By replacing stationary with rotary screens that were continuously cleaned, larger supplies of respirable dust were obtained without interruption. A ginned and a waste cotton were used to test two methods of separation: a rotating 38-micr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of environmental monitoring : JEM
دوره 10 5 شماره
صفحات -
تاریخ انتشار 2008