Improved Accuracy of Spot Search on HPV DNA Microarray Chip

نویسندگان

  • Jae-Hong Min
  • Chan-Young Park
  • Yu-Seop Kim
  • Hye-Jeong Song
  • Jong-Dae Kim
چکیده

There are two methods to search the spot in the microarray DNA chip: Grid method and Circle template image method. However, these methods have the drawback that they are slow. To solve this problem in a recent study, applying the running algorithm using a box template image reduced the time by 1/10. However, there was a drop in accuracy when comparing accuracy with Grid and Circle template matching methods. Since the size of the box template image used in the previous study is the same as the spot size, the circular spot and the template image do not coincide with each other. Therefore, we show the difference of accuracy by changing the size of the template image. In this paper, we measure the accuracy of the box template image by size and find the best performance. As a result, it seems to be grounds for selecting the most appropriate size box template image according to spot size.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined SYBR Green real-time polymerase chain reaction and microarray method for the simultaneous determination of human papillomavirus loads and genotypes

OBJECTIVE The aim of this study was to describe the principle of the Cheil HPV DNA Chip assay and evaluate its accuracy. In order to quantify the human papillomavirus (HPV) load and identify HPV genotypes simultaneously, this assay combined the two methods: SYBR Green quantitative real-time polymerase chain reaction (PCR) and DNA microarray. METHODS We designed novel consensus primer sets tha...

متن کامل

Optical detection of nanoparticle-enhanced human papillomavirus genotyping microarrays

In this study, we propose a new detection method of nanoparticle-enhanced human papillomavirus genotyping microarrays using a DVD optical pick-up with a photodiode. The HPV genotyping DNA chip was labeled using Au/Ag core-shell nanoparticles, prepared on a treatment glass substrate. Then, the bio information of the HPV genotyping target DNA was detected by measuring the difference of the optica...

متن کامل

Comparison of the Cobas 4800 HPV and HPV 9G DNA Chip Tests for Detection of High-Risk Human Papillomavirus in Cervical Specimens of Women with Consecutive Positive HPV Tests But Negative Pap Smears

Detecting high-risk (HR) HPV is important for clinical management of women with persistent HPV-positive and Pap-negative results. The Cobas 4800 HPV test is the first FDA-approved HPV DNA test that can be used alone as a first-line screening tool. The HPV 9G DNA chip test is a PCR-based DNA microarray assay. We evaluated the patients of consecutive HPV-positivity on HPV 9G DNA chip test without...

متن کامل

Clinical Significance of an HPV DNA Chip Test with Emphasis on HPV-16 and/or HPV-18 Detection in Korean Gynecological Patients

BACKGROUND Human papillomavirus (HPV) is a major risk factor for cervical cancer. METHODS We evaluated the clinical significance of the HPV DNA chip genotyping assay (MyHPV chip, Mygene Co.) compared with the Hybrid Capture 2 (HC2) chemiluminescent nucleic acid hybridization kit (Digene Corp.) in 867 patients. RESULTS The concordance rate between the MyHPV chip and HC2 was 79.4% (kappa coef...

متن کامل

Dapple: Improved Techniques for Finding Spots on DNA Microarrays

A key step in experiments using DNA microarrays is locating the thousands of individual spots in a scanned array image. Each spot provides quantitative information about a distinct DNA sequence, so it is imperative that spots be found and quantitated accurately. Spot finding is complicated by variations in the positions and sizes of spots and by the presence of artifacts and background noise in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017