The effect of distal screw orientation on the intrinsic stability of a tibial intramedullary nail.

نویسندگان

  • A L Chen
  • N C Tejwani
  • T N Joseph
  • F J Kummer
  • K J Koval
چکیده

To compare the intrinsic stability of two distal interlocking screw orientations for tibial nailing of distal third tibial diaphyseal fractures without isthmal support, six Depuy (Warsaw, Indiana) tibial intramedullary nails were implanted in simulated distal tibiae. The constructs received both two parallel (medial to lateral) and two perpendicular (one medial to lateral, one anterior to posterior) distal interlocking screws in a random order Angular, translational, and torsional displacements of the nails were measured in response to 70 N proximal applications of anterior, posterior, medial, and lateral loads, and a 7.7 Newton-meter torsional load. There were no differences in medial or lateral angulations between the screw orientations (average: 2.5 degrees, p > 0.8). Angulation in the sagittal plane (anterior and posterior) was slightly less for parallel screw fixation (1.6 degrees versus 2.4 degrees), but this was not statistically significant (p > 0.1). Rotational angulation was higher in the parallel (average: 9.9 degrees) versus the perpendicular (average: 8.1 degrees) screw orientation, but these results were not statistically significant (p > 0.1). Pure translation did not occur in either the parallel or perpendicular screw orientations. These results indicate that fixation stability of these tibial intramedullary nails is not significantly influenced by distal interlocking screw orientation in response to sagittal, coronal, or rotational forces.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Two Distal Interlocking Screw Configuration and Orientation on Intramedullary Nail Stability: A Biomechanical Study

INTRODUCTION: Long bone diaphyseal fractures are a very common injury encountered in orthopedic practice. This type of fracture is often treated using an intramedullary (IM) nail. In this day and age there are many options in regards to the orientation of the distal interlocking screws. The goal of this study was to determine if the distance between two distal locking screws affects the stabili...

متن کامل

Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing

Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experimen...

متن کامل

Intramedullary fixation of proximal tibial fractures

is challenging owing to the relatively high chance of displacement during nail insertion. The stability of the proximal fixation is inferior because of the wider diameter of the intramedullary canal in the metaphysis. This has led to the use of Poller screws for additional blocking during intramedullary fixation of proximal or distal tibial fractures.1 The effects of Poller screw is two-fold. F...

متن کامل

Distal Tibial Metaphyseal Fractures: Does Blocking Screw Extend the Indication of Intramedullary Nailing?

Aim. To evaluate the clinical use of blocking screws as a supplement to stability in distal tibial metaphyseal fractures treated with statically locked intramedullary nail. Main Outcome Measurement. Alignment and reduction preoperatively, postoperatively, and at healing were the main outcome measured with an emphasis on maintenance of initial reduction on followup. Patients and Methods. This wa...

متن کامل

Extending the indications of intramedullary nailing with the Expert Tibial Nail.

Numerous modifications in nail and screw design have led to the development of the Expert Tibial Nail. It enables the surgeon to further extend the spectrum of fractures eligible for intramedullary nailing. In the proximal metaphysis spongious bone screws achieve an optimized purchase in the cancellous bone. Multidirectional interlocking screws ensure that alignment can be well maintained and s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bulletin (Hospital for Joint Diseases (New York, N.Y.))

دوره 60 2  شماره 

صفحات  -

تاریخ انتشار 2001