Comparison of cross-linked polyethylene materials for orthopaedic applications.

نویسندگان

  • John P Collier
  • Barbara H Currier
  • Francis E Kennedy
  • John H Currier
  • Graham S Timmins
  • Simon K Jackson
  • Robin L Brewer
چکیده

Cross-linked polyethylenes are being marketed by orthopaedic manufacturers to address the problem of osteolysis caused by polyethylene particulate wear debris. Wear testing of these cross-linked polyethylenes in hip simulators has shown dramatic reduction in wear rate compared with standard ultrahigh molecular weight polyethylene, either gamma irradiated in air or nitrogen - or ethylene oxide-sterilized. However, this reduction in wear rate is not without cost. The cross-linking processes can result in materials with lower mechanical properties than standard ultrahigh molecular weight polyethylene. To evaluate the effect of the various cross-linking processes on physical and mechanical properties of ultrahigh molecular weight polyethylene, commercially available cross-linked polyethylenes from six orthopaedic manufacturers were tested. This study was the culmination of collaboration with these manufacturers, who provided cross-linked polyethylene for this study, wear characteristics of the material they provided, and review of the physical and mechanical properties measure for their polyethylene. Cross-linked materials were evaluated as received and after an accelerated aging protocol. Free radical identity and concentration, oxidation, crystallinity, melt temperature, ultimate tensile strength, elongation at break, tensile stress at yield, and toughness are reported for each material. By comparing these physical and mechanical properties, surgeons can evaluate the trade-off that results from developing materials with substantially lower wear rates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cross-linked polyethylene and bisphosphonate therapy for osteolysis in total hip arthroplasty: a case report.

A 39-year-old woman underwent bilateral total hip arthroplasty with conventional, ethylene oxide-sterilised liners when she was a subject in a radiostereometric analysis study. Within 2 years she had rapid polyethylene wear with aggressive, asymptomatic, and periprosthetic osteolysis on both sides. Oral alendronate therapy halted the progression of osteolysis over a year and revision to cross-l...

متن کامل

Genipin cross-linked electrospun chitosan-based nanofibrous mat as tissue engineering scaffold

Objective(s): To improve water stability of electrospun chitosan/ Polyethylene oxide (PEO) nanofibers, genipin, a biocompatible and nontoxic agent, was used to crosslink chitosan based nanofibers.  Materials and Methods: Different amounts of genipin were added to the chitosan/PEO solutions, chitosan/PEO weight ratio 90/10 in 80 % acetic acid, and the solutions were then electrospun to form nano...

متن کامل

Wear and migration of highly cross-linked and conventional cemented polyethylene cups with cobalt chrome or Oxinium femoral heads: a randomized radiostereometric study of 150 patients.

This randomized study was performed to compare wear and migration of five different cemented total hip joint articulations in 150 patients. The patients received either a Charnley femoral stem with a 22.2 mm head or a Spectron EF femoral stem with a 28 mm head. The Charnley articulated with a γ-sterilized Charnley Ogee acetabular cup. The Spectron EF was used with either EtO-sterilized non-cros...

متن کامل

Biotribology of a vitamin E-stabilized polyethylene for hip arthroplasty - Influence of artificial ageing and third-body particles on wear.

The objective of our study was to evaluate the influence of prolonged artificial ageing on oxidation resistance and the subsequent wear behaviour of vitamin E-stabilized, in comparison to standard and highly cross-linked remelted polyethylene (XLPE), and the degradation effect of third-body particles on highly cross-linked remelted polyethylene inlays in total hip arthroplasty. Hip wear simulat...

متن کامل

Investigating the Effect of Using Cross-Linked Polyethylene Waste as Fine Aggregate on Mechanical Properties of Hot Mix Asphalt

Cross-linked polyethylene (XLPE) is an appropriate insulating material for high-voltage cables which has been widely used as electrical cable coating. In this study, Crushed XLPE wastes with different volume percentages (25, 50, and 75%) were used in hot mix asphalt (HMA) as a substitute for fine aggregates remained on sieve no. 8 whose size varies from 1.18 to 2.36 mm. The dynamic stiffness (i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 414  شماره 

صفحات  -

تاریخ انتشار 2003