Comparison of cytokine levels and metabolic parameters of stored platelet concentrates of the Fundação Hemominas, Belo Horizonte, Brazil

نویسندگان

  • Evaldo José Costa
  • Tânia Mara Pinto Dabé Guimarães
  • Nathalia Correia de Almeida
  • Vicente de Paulo Coelho Peixoto de Toledo
چکیده

BACKGROUND Prolonged storage of platelets could improve availability and logistical management and decrease wastage. Immunobiochemical methods can be used to guarantee the quality of platelets after prolonged storage. OBJECTIVE The aim of this study was to compare storage-related changes in buffy coat-derived platelet concentrations versus platelet-rich plasmal. METHODS Units of whole blood were drawn using a quadruple-bag blood container system. Platelet-rich plasma and buffy coat prepared from whole blood following standard methods were stored for 9 days. During this period test samples were aseptically collected for analysis on Days 1, 2, 3, 5, 7 and 9. RESULTS The highest CD42b expression was greater than 95%. The percentage of CD62p was significantly lower than the CD42b expression. The pH remained fairly stable during storage. Measurement of pO(2) and pCO(2) showed that oxygen levels were significantly higher than carbon dioxide levels. There were no significant differences in bicarbonate levels, glucose consumption and lactate production between the groups. The swirling effect with platelet-rich plasma samples decreased after 5 days of storage and after 7 days of storage for buffy coat samples. There was a significant twenty-fold increase in the mean IL-1β after 5 days of storage for both groups. Slight increases in IL-6 and IL-8 levels were seen at 5 days. CONCLUSION The quality of platelet concentrates remained acceptable during 7 days of storage in respect to the swirling effect, pH and platelet activation. There were no significant differences between buffy coat-derived platelets and platelet-rich plasma in this study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Halogenation as a Strategy to Improve Antiplasmodial Activity: A Report of New 3-Alkylpyridine Marine Alkaloid Analogs

Introduction: Due to the emergence of resistance to antimalarial drugs as well as the lack of vaccination for malaria, there is an urgent demand for the development of new antimalarial alternatives. Recently, our research group developed a new set of 3-alkylpyridine marine alkaloid analogs, of which a compound known as compound 5 was found to be inactive against Plasmodium ...

متن کامل

Differential serodiagnosis of human infections caused by Trypanosoma cruzi and Leishmania spp. using ELISA with a recombinant antigen (rTc24).

Departamento de Clínica Médica, Faculdade de Medicina, Universidade Federal de Minas Gerais, Av. Alfredo Balena 190, 30130-100 Belo Horizonte, MG, Brasil *Centro de Pesquisas René Rachou-FIOCRUZ, Av. Augusto de Lima 1715, 30190-002 Belo Horizonte, MG, Brasil **Departamento de Parasitologia, Instituto de Ciências Biológicas da Universidade Federal de Minas Gerais, Av. Antônio Carlos 6.627, 31270...

متن کامل

Quality of bevacizumab (Avastin®) repacked in single-use glass vials for intravitreal administration Avaliação da qualidade do bevacizumabe (Avastin®) fracionado em frascos de vidro de dose única para administração intravítrea

1 Faculty of Pharmacy, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil. 2 Chemistry Laboratory, Fundação Ezequiel Dias, Belo Horizonte, MG, Brazil. 3 Institute of Biological Sciences, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil. 4 Department of Ophthalmology, Faculty of Medicine of Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil. 5 Pha...

متن کامل

Evaluation of Biochemical Parameters of Platelet Concentrates Stored in Plasma or in A Platelet Additive Solution (Composol)

Abstract Objective Removing plasma from the platelet concentrate (PC) medium could be an effective way to increase the safety of this product. The goal of this study was to compare PC stored in plasma or in an additive solution (Composol) with in vitro testing. Materials and Methods Fifty-four single donor PCs were prepared from Iranian Blood Transfusion Organization (IBTO). Each PC unit wa...

متن کامل

The impact of 18F-FDG PET/CT in staging of non-small cell lung cancer patients: the key to improve patient treatment strategy

1 Prefeitura Municipal de Belo Horizonte, Posto de Saúde. Belo Horizonte, MG Brazil. 2 Elcordis Centro de Diagnósticos Ltda. Contagem, MG Brazil. 3 Fundação Hospitalar do Estado de Minas Gerais-FHEMIG. Belo Horizonte, MG Brazil. 4 Hospital Julia Kubistchek, Cirurgia Torácica. Belo Horizonte, MG Brazil. 5 Universidade Federal de Minas Gerais-UFMG, Faculdade de Medicina, Departamento de Anatomia ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 34  شماره 

صفحات  -

تاریخ انتشار 2012