Improved left ventricular endocardial border delineation and opacification with OPTISON (FS069), a new echocardiographic contrast agent. Results of a phase III Multicenter Trial.

نویسندگان

  • J L Cohen
  • J Cheirif
  • D S Segar
  • L D Gillam
  • J S Gottdiener
  • E Hausnerova
  • D E Bruns
چکیده

OBJECTIVES The echocardiographic contrast-enhancing effects and safety profile of ALBUNEX (a suspension of air-filled albumin microspheres) were compared with the new contrast agent OPTISON (formerly FS069: a suspension of albumin microspheres containing the gas perfluoropropane) in 203 patients with inadequate noncontrast echocardiograms. BACKGROUND The efficacy of ALBUNEX has been limited by its short duration of action. By using perfluoropropane instead of air within the microsphere, its duration of action is increased. METHODS Each patient received ALBUNEX (0.8 and 0.22 mL/kg) and OPTISON (0.2, 0.5, 3.0, and 5.0 mL) on separate days a minimum of 48 hours apart. Echocardiograms were evaluated for increase in left ventricular (LV) endocardial border length, degree of LV opacification, number of LV endocardial border segments visualized, conversion from a nondiagnostic to a diagnostic echocardiogram, and duration of contrast enhancement. A thorough safety evaluation was conducted. RESULTS Compared with ALBUNEX, OPTISON more significantly improved every measure of contrast enhancement. OPTISON increased well-visualized LV endocardial border length by 6.0+/-5.1, 6.9+/-5.4, 7.5+/-4.7, and 7.6+/-4.8 cm, respectively, for each of the four doses, compared with only 2.2+/-4.5 and 3.4+/-4.6 cm, respectively, for the two ALBUNEX doses (p < 0.001). 100% LV opacification was achieved in 61%, 73%, 87%, and 87% of the patients with the four doses of OPTISON, but in only 16% and 36% of the patients with the two ALBUNEX doses (p < 0.001). Conversion of nondiagnostic to diagnostic echocardiograms with contrast occurred in 74% of patients with the optimal dose of OPTISON (3.0 mL) compared with only 26% with the optimal dose of ALBUNEX (0.22 mL/kg) (p < 0.001). The duration of contrast effect was also significantly greater with OPTISON than with ALBUNEX. In a subset of patients with potentially poor transpulmonary transit of contrast (patients with chronic lung disease or dilated cardiomyopathy), OPTISON more significantly improved the same measures of contrast enhancement compared with ALBUNEX and did so to the same extent as in the overall population. Side effects were similar and transient with the two agents. CONCLUSION OPTISON appears to be a safe, well-tolerated echocardiographic contrast agent that is superior to ALBUNEX.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endocardial Border Detection in Contrast Enhanced Echocardiographic Cineloops using a Pulse Coupled Neural Network

Endocardial border detection is a crucial step for the quantitative analysis of overall and regional left ventricular function from echocardiographic images. Echocardiographic contrast agents with transpulmonary passage are being used increasingly in clinical practice for left ventricular cavity opacification. We investigate the feasibility of using pulse coupled neural networks to identify the...

متن کامل

Contrast echocardiography: current and future applications.

Recent updates in the field of echocardiography have resulted in improvements in image quality, especially in those patients whose ultrasonographic (ultrasound) evaluation was previously suboptimal. Intravenous contrast agents are now available in the United States and Europe for the indication of left ventricular opacification and enhanced endocardial border delineation. The use of contrast en...

متن کامل

Endocardial border delineation capability of a novel multimodal polymer-shelled contrast agent

BACKGROUND A novel polymer-shelled contrast agent (CA) with multimodal and target-specific potential was developed recently. To determine its ultrasonic diagnostic features, we evaluated the endocardial border delineation as visualized in a porcine model and the concomitant effect on physiological variables. METHODS Three doses of the novel polymer-shelled CA (1.5 ml, 3 ml, and 5 ml [5 × 10(8...

متن کامل

Left ventricular opacification during selective intracoronary injection of echocardiographic contrast in patients with hypertrophic cardiomyopathy.

Percutaneous alcohol ablation of the interventricular septum via the first septal perforator branch of the left anterior descending artery can successfully treat dynamic left ventricular outflow tract obstruction in patients with hypertrophic cardiomyopathy. Increasingly, echocardiographic contrast agents are used before alcohol injection to identify the perfusion bed of the septal perforator v...

متن کامل

Methods for assessment of left ventricular systolic function in technically difficult patients with poor imaging quality.

The assessment of left ventricular (LV) systolic function is often the most important information obtained during clinical echocardiography. Although LV systolic function may be visually estimated in many patients with or without contrast opacification, technically difficult patients may require alternative methods for evaluating LV systolic function. In this review, the authors describe severa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 32 3  شماره 

صفحات  -

تاریخ انتشار 1998