Selecting a Primary Frequency Standard for a Calibration Laboratory

نویسنده

  • Michael A. Lombardi
چکیده

Calibration laboratories can choose from a variety of frequency standards, including quartz oscillators, atomic oscillators, and oscillators disciplined to agree with reference signals from the Global Positioning System (GPS) satellites or other sources. The frequency calibration and measurement capability of a laboratory is largely determined by the type of primary frequency standard* that is chosen. This paper presents an overview of the various types of commercially available frequency standards. It discusses their specifications, and the pros and cons of owning and operating each type of standard. It also presents long-term performance data from a number of calibration laboratory frequency standards that are monitored by the National Institute of Standards and Technology (NIST) through its remote calibration services.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Some steps towards establishing a tertiary standard dosimetry laboratory at a radiotherapy department

Background: In order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. When the calibration procedure is performed for a reference dosimeter in the 60Co beam of a Secondary Standard Dosimetry Laboratory (SSDL), the total uncertainty in absorbed dose to water (Dw) is estimated to be approximately 1.5%. This study attempts...

متن کامل

The Use of GPS Disciplined Oscillators as Primary Frequency Standards for Calibration and Metrology Laboratories

An increasing number of calibration and metrology laboratories now employ a Global Positioning System disciplined oscillator (GPSDO) as their primary standard for frequency. GPSDOs have the advantage of costing much less than cesium standards, and they serve as “self-calibrating” standards that should not require adjustment or calibration. These attributes make them an attractive choice for man...

متن کامل

Simultaneous Determination of Hydrochlorothiazide and Enalapril Maleate in Pharmaceutical Formulations Using Fourier Transform Infrared Spectrometry

A new Fourier Transform-Infra Red (FT-IR) spectrometric method was developed for assaying hydrochlorothiazide (HCT) and enalapril maleate (ENM) in binary solid pharmaceutical formulations. Multivariate Partial Least Squares (PLS) method was used for calibration of derivative spectral data. Acetonitrile was used as solvent due to its spectral tran...

متن کامل

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...

متن کامل

Report of Time and Frequency Activities at NICT (2012-2015)

The National Institute of Information and Communications Technology (NICT), an incorporated administrative agency, was established in 2004 with its large part inherited from the Communications Research Laboratory (CRL). The activity of time and frequency standards is conducted within the Space-Time Standards Laboratory of the Applied Electromagnetic Research Institute, this group itself compris...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008