Epidural intracranial pressure measurement in rats using a fiber-optic pressure transducer.

نویسندگان

  • Lucy Murtha
  • Damian McLeod
  • Neil Spratt
چکیده

Elevated intracranial pressure (ICP) is a significant problem in several forms of ischemic brain injury including stroke, traumatic brain injury and cardiac arrest. This elevation may result in further neurological injury, in the form of transtentorial herniation(1,2,3,4), midbrain compression, neurological deficit or increased cerebral infarct(2,4). Current therapies are often inadequate to control elevated ICP in the clinical setting(5,6,7). Thus there is a need for accurate methods of ICP measurement in animal models to further our understanding of the basic mechanisms and to develop new treatments for elevated ICP. In both the clinical and experimental setting ICP cannot be estimated without direct measurement. Several methods of ICP catheter insertion currently exist. Of these the intraventricular catheter has become the clinical 'gold standard' of ICP measurement in humans(8). This method involves the partial removal of skull and the instrumentation of the catheter through brain tissue. Consequently, intraventricular catheters have an infection rate of 6-11%(9). For this reason, subdural and epidural cannulations have become the preferred methods in animal models of ischemic injury. Various ICP measurement techniques have been adapted for animal models, and of these, fluid-filled telemetry catheters(10) and solid state catheters are the most frequently used(11,12,13,14,15). The fluid-filled systems are prone to developing air bubbles in the line, resulting in false ICP readings. Solid state probes avoid this problem (Figure 1). An additional problem is fitting catheters under the skull or into the ventricles without causing any brain injury that might alter the experimental outcomes. Therefore, we have developed a method that places an ICP catheter contiguous with the epidural space, but avoids the need to insert it between skull and brain. An optic fibre pressure catheter (420LP, SAMBA Sensors, Sweden) was used to measure ICP at the epidural location because the location of the pressure sensor (at the very tip of the catheter) was found to produce a high fidelity ICP signal in this model. There are other manufacturers of similar optic fibre technologies(13) that may be used with our methodology. Alternative solid state catheters, which have the pressure sensor located at the side of the catheter tip, would not be appropriate for this model as the signal would be dampened by the presence of the monitoring screw. Here, we present a relatively simple and accurate method to measure ICP. This method can be used across a wide range of ICP related animal models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sonography for determining the optic nerve sheath diameter with increasing intracranial pressure in a porcine model.

OBJECTIVES This study investigated whether it is feasible to use sonography to monitor changes in the optic nerve sheath diameter in a porcine model. METHODS A fiber-optic intracranial pressure transducer was surgically placed through the frontal sinus directly into the brain parenchyma of adult Yorkshire pigs (n = 5). A second bolt was placed on the contralateral side for intraparenchymal fl...

متن کامل

A Novel Rat Model to Study the Role of Intracranial Pressure Modulation on Optic Neuropathies

Reduced intracranial pressure is considered a risk factor for glaucomatous optic neuropathies. All current data supporting intracranial pressure as a glaucoma risk factor comes from retrospective and prospective studies. Unfortunately, there are no relevant animal models for investigating this link experimentally. Here we report a novel rat model that can be used to study the role of intracrani...

متن کامل

Effect of scuba-diving on optic nerve and sheath diameters

  Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated.   Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...

متن کامل

Simultaneous Magnetic Resonance Imaging and Consolidation Measurement of Articular Cartilage

Magnetic resonance imaging (MRI) offers the opportunity to study biological tissues and processes in a non-disruptive manner. The technique shows promise for the study of the load-bearing performance (consolidation) of articular cartilage and changes in articular cartilage accompanying osteoarthritis. Consolidation of articular cartilage involves the recording of two transient characteristics: ...

متن کامل

Imaging intracranial pressure: an introduction to ultrasonography of the optic nerve sheath.

I N clinical practice it is important to determine whether increased intracranial pressure is present. This allows one to alter hemodynamic management, predict the potential for neurologic deterioration, and guide therapeutic removal of cerebrospinal fluid or avoid such withdrawal. A spinal leak or drainage of cerebrospinal fluid can create an imbalance between supratentorial and infratentorial...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of visualized experiments : JoVE

دوره 62  شماره 

صفحات  -

تاریخ انتشار 2012