Delayed cardiac perforation of the Durata implantable cardioverter-defibrillator lead more than 1 year after implantation
نویسندگان
چکیده
Introduction The rate of implantable cardioverter-defibrillator (ICD) lead perforations has been reported to be in the range of 0.6%– 5.2%, with the majority of cases occurring within 1 month of implantation. However, isolated reports of delayed ICD lead perforations occurring more than 1 year and up to 3 years after implantation have been described. Here, we present a case of a patient with a Durata ICD lead who presented with syncope and cardiac tamponade due to lead perforation more than 1 year after implantation.
منابع مشابه
Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملCardiac Perforation Associated with a Pacemaker or ICD Lead
Cardiac perforation after pacemaker or implantable cardioverter-defibrillator (ICD) implantation is an infrequent complication. The reported rates of perforation are 0.1-0.8% after pacemaker implantation and 0.6-5.2% after ICD implantation (Khan et al., 2005; Mahapatra et al., 2005). From 1994 to 2009, total 1026 permanent pacemakers and ICDs were implanted in my lab, and two cases (0.2%) devel...
متن کاملDelayed Perforation of the Right Ventricular Wall by a Single Standard-Caliber Implantable Cardioverter-Defibrillator Lead Detected by Multidetector Computed Tomography
We present an unusual case of a delayed right ventricular perforation by a single standard-caliber implantable cardioverter-defibrillator lead, which manifested 14 days after implantation. Multidetector computed tomography could clearly display the lead perforation, and allow for identification of the associated sequelae such as pericardial effusion and planning the lead extraction strategy.
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملTransvenous Implantable Cardioverter-Defibrillator Lead Reliability: Implications for Postmarket Surveillance
BACKGROUND As implantable cardioverter-defibrillator technology evolves, clinicians and patients need reliable performance data on current transvenous implantable cardioverter-defibrillator systems. In addition, real-world reliability data could inform postmarket surveillance strategies directed by regulators and manufacturers. METHODS AND RESULTS We evaluated Medtronic Sprint Quattro, Boston...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2 شماره
صفحات -
تاریخ انتشار 2016