Kinetic study of uranium residue dissolution in ammonium carbonate media
نویسندگان
چکیده
The purpose of this study was to determine the kinetics of the dissolution of a uranium residue in ammonium carbonate media. The residue is generated in the production of medical isotopes. The effects of parameters, such as varying peroxide and carbonate concentrations, dissolution time as well as temperature on the extraction rate have been separately studied. Results indicate complete dissolution of the residue at 60 °C, after 30 min, in ammonium carbonate solution enriched with hydrogen peroxide. The yield and rate of uranium extraction were found to increase as a function of both temperature, in the range of 25-60 °C, and hydrogen peroxide concentration. The extraction process was governed by chemical reaction as the activation energy was found to be 45.5 kJ/mol. The order of reaction with respect to uranium concentration was found to be approximately first order.
منابع مشابه
Preparation of U3O8 by Calcination from Ammonium Uranyl Carbonate Using Response Surface Methodology: Process Optimization
The parameters to prepare U3O8 by calcination from ammonium uranyl carbonate were optimized by using response surface methodology. A quadratic equation model for the value of total uranium and U4+ of triuranium octaoxide was built and the effects of main factors and their corresponding relationships were obtained. The statistical analysis of the results indi...
متن کاملDissolution of uranyl microprecipitates in subsurface sediments at Hanford Site, USA
The dissolution of uranium was investigated from contaminated sediments obtained at the US. Department of Energy (U.S. DOE) Hanford site. The uranium existed in the sediments as uranyl silicate microprecipitates in fractures, cleavages, and cavities within sediment grains. Uranium dissolution was studied in Na, Na-Ca, and NH4 electrolytes with pH ranging from 7.0 to 9.5 under ambient CO2 pressu...
متن کاملThe Effect of In Vitro Dissolution System Parameters for Measuring the Solubility of Uranium Aerosols
The use of in vitro dissolution tests for estimating the in vivo solubility of inhaled radioactive aerosols is being increasingly considered for both prospective and retrospective exposure/dose assessments, mainly because such tests are relatively simple to conduct (compared to in vivo experiments) and because current respiratory tract dosimetry models (e.g., ICRP Publication 66, 1994) provide ...
متن کاملDevelopment of a versatile sample preparation method and its application for rare-earth pattern and Nd isotope ratio analysis in nuclear forensics
An improved sample preparation procedure for trace-levels of lanthanides in uranium-bearing samples was developed. The method involves a simple co-precipitation using Fe(III) carrier in ammonium carbonate medium to remove the uranium matrix. The procedure is an effective initial pre-concentration step for the subsequent extraction chromatographic separations. The applicability of the method was...
متن کاملLong-term in situ oxidation of biogenic uraninite in an alluvial aquifer: impact of dissolved oxygen and calcium.
Oxidative dissolution controls uranium release to (sub)oxic pore waters from biogenic uraninite produced by natural or engineered processes, such as bioremediation. Laboratory studies show that uraninite dissolution is profoundly influenced by dissolved oxygen (DO), carbonate, and solutes such as Ca(2+). In complex and heterogeneous subsurface environments, the concentrations of these solutes v...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 302 شماره
صفحات -
تاریخ انتشار 2014