Relative motion at the bone-prosthesis interface.

نویسندگان

  • M Keja
  • H W Wevers
  • D Siu
  • H Grootenboer
چکیده

Bone ingrowth in porous surfaces of human joint implants is a desired condition for long-term fixation in patients who are physically active (such as in sport or work). It is generally recognized that little actual bone ingrowth occurs. The best clinical results report between 10 and 20% of the total prosthetic surface in contact with bone will feature good bone ingrowth. One inhibiting factor is the relative motion of the bone with respect to the implant during load-bearing. This study investigated mathematically the interface micromotion (transverse reversible relative motion) between a flat metal tibial prosthetic surface of a prototype implant, and the bone at the resection site. The aim was to assess the effect of perimeter fixation versus midcondylar pin fixation and the effect of plate thickness and plate stiffness. Results showed that in the prototype design the largest reversible relative bone motion occurred at the tibial eminence. By design, the skirt fixation at the perimeter would prevent bone motion. A PCA (Howmedica Inc.) prosthesis has been widely used clinically and was chosen for a control because its fixation by two pegs beneath the condyles is a common variation on the general design of a relatively thick and stiff metal tibial support tray with pegs in each condylar area. The PCA tibial prosthesis showed the largest bone motion at the perimeter along the midcondylar mediolateral line, while being zero at the pegs. Maximum relative bone motion for the prototype was 37 μm and for the control was 101 μm. Averaged values showed the prototype to have 38% of the relative reversible bone motion of the control (PCA).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Surface Coating

The short-term clinical failures of cementless stems, such as proximal bone resorption and thigh pain, have limited their acceptance despite the potential long-term benefits of biological fixation for younger and more active patients. The clinical problems are believed to be related to failure at the bone-stem interface. By optimizing the design of the prosthesis to prevent or minimize failure ...

متن کامل

Friction and stem stiffness affect dynamic interface motion in total hip replacement.

Large cyclic movements between the femoral stem and bone during the first weeks after total hip arthroplasty may hamper bone ingrowth and adversely affect the eventual success of the arthroplasty. Little is known, however, about the magnitude of the motions and its relationship to design and surgical factors. A two-dimensional finite element model of a cementless prosthesis inserted into the pr...

متن کامل

Initial stability of a new uncemented short-stem prosthesis, Spiron®, in dog bone.

BACKGROUND Use of the proximal part of the femur in total hip arthroplasty enables preservation of the distal femur for later revisions. To use this advantage, different types of short-stem prosthesis have been developed in recent years. Although cementless hip arthroplasty is not common in the treatment of canine osteoarthritis, the use of cementless short-stems might be an alternative therapy...

متن کامل

Radial Head Prosthesis Removal:a Retrospective Case Series of 14 Patients

Background:  The purpose of this study was to report the preoperative complaints and postoperative outcome of patients after removal of the radial head prosthesis.   Methods:  This is a retrospective review of 14 adult patients (6 females and 8 males) from 2007 to 2011, who underwent radial head prosthesis removal by three surgeons. The average time between implantation and removal was 23 month...

متن کامل

Quantitative analysis of bone reactions to relative motions at implant-bone interfaces.

Connective soft tissues at the interface between implants and bone, such as in human joint replacements, can endanger the stability of the implant fixation. The potential of an implant to generate interface bone resorption and form soft tissue depends on many variables, including mechanical ones. These mechanical factors can be expressed in terms of relative motions between bone and implant at ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical biomechanics

دوره 9 5  شماره 

صفحات  -

تاریخ انتشار 1994